Your browser doesn't support javascript.
loading
Tissue viscoelasticity is related to tissue composition but may not fully predict the apparent-level viscoelasticity in human trabecular bone - An experimental and finite element study.
Ojanen, X; Tanska, P; Malo, M K H; Isaksson, H; Väänänen, S P; Koistinen, A P; Grassi, L; Magnusson, S P; Ribel-Madsen, S M; Korhonen, R K; Jurvelin, J S; Töyräs, J.
Afiliação
  • Ojanen X; Department of Applied Physics, University of Eastern Finland, POB 1627, FI-70211 Kuopio, Finland. Electronic address: xiaowei.ojanen@uef.fi.
  • Tanska P; Department of Applied Physics, University of Eastern Finland, POB 1627, FI-70211 Kuopio, Finland.
  • Malo MKH; Department of Applied Physics, University of Eastern Finland, POB 1627, FI-70211 Kuopio, Finland.
  • Isaksson H; Department of Biomedical Engineering, Lund University, POB 118, 221 00 Lund, Sweden.
  • Väänänen SP; Department of Applied Physics, University of Eastern Finland, POB 1627, FI-70211 Kuopio, Finland; Diagnostic Imaging Center, Kuopio University Hospital, POB 100, FI-70029 Kuopio, Finland.
  • Koistinen AP; SIB Labs, University of Eastern Finland, PO Box 1627, FI-70211 Kuopio, Finland.
  • Grassi L; Department of Biomedical Engineering, Lund University, POB 118, 221 00 Lund, Sweden.
  • Magnusson SP; Department of Physical Therapy, Bispebjerg Hospital, Denmark; Institute of Sports Medicine, Department of Orthopaedic Surgery M, Bispebjerg Hospital and Center for Healthy Aging, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
  • Ribel-Madsen SM; Institute of Sports Medicine, Department of Orthopaedic Surgery M, Bispebjerg Hospital and Center for Healthy Aging, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
  • Korhonen RK; Department of Applied Physics, University of Eastern Finland, POB 1627, FI-70211 Kuopio, Finland; Diagnostic Imaging Center, Kuopio University Hospital, POB 100, FI-70029 Kuopio, Finland.
  • Jurvelin JS; Department of Applied Physics, University of Eastern Finland, POB 1627, FI-70211 Kuopio, Finland.
  • Töyräs J; Department of Applied Physics, University of Eastern Finland, POB 1627, FI-70211 Kuopio, Finland; Diagnostic Imaging Center, Kuopio University Hospital, POB 100, FI-70029 Kuopio, Finland.
J Biomech ; 65: 96-105, 2017 Dec 08.
Article em En | MEDLINE | ID: mdl-29108850
Trabecular bone is viscoelastic under dynamic loading. However, it is unclear how tissue viscoelasticity controls viscoelasticity at the apparent-level. In this study, viscoelasticity of cylindrical human trabecular bone samples (n=11, male, age 18-78 years) from 11 proximal femurs were characterized using dynamic and stress-relaxation testing at the apparent-level and with creep nanoindentation at the tissue-level. In addition, bone tissue elasticity was determined using scanning acoustic microscope (SAM). Tissue composition and collagen crosslinks were assessed using Raman micro-spectroscopy and high performance liquid chromatography (HPLC), respectively. Values of material parameters were obtained from finite element (FE) models by optimizing tissue-level creep and apparent-level stress-relaxation to experimental nanoindentation and unconfined compression testing values, respectively, utilizing the second order Prony series to depict viscoelasticity. FE simulations showed that tissue-level equilibrium elastic modulus (Eeq) increased with increasing crystallinity (r=0.730, p=.011) while at the apparent-level it increased with increasing hydroxylysyl pyridinoline content (r=0.718, p=.019). In addition, the normalized shear modulus g1 (r=-0.780, p=.005) decreased with increasing collagen ratio (amide III/CH2) at the tissue-level, but increased (r=0.696, p=.025) with increasing collagen ratio at the apparent-level. No significant relations were found between the measured or simulated viscoelastic parameters at the tissue- and apparent-levels nor were the parameters related to tissue elasticity determined with SAM. However, only Eeq, g2 and relaxation time τ1 from simulated viscoelastic values were statistically different between tissue- and apparent-levels (p<.01). These findings indicate that bone tissue viscoelasticity is affected by tissue composition but may not fully predict the macroscale viscoelasticity in human trabecular bone.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fêmur / Osso Esponjoso Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fêmur / Osso Esponjoso Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article