Your browser doesn't support javascript.
loading
Peripheral airway dysfunction and relationship with symptoms in smokers with preserved spirometry.
Jetmalani, Kanika; Thamrin, Cindy; Farah, Claude S; Bertolin, Amy; Chapman, David G; Berend, Norbert; Salome, Cheryl M; King, Gregory G.
Afiliação
  • Jetmalani K; The Woolcock Emphysema Centre, Woolcock Institute of Medical Research, Glebe, NSW, Australia.
  • Thamrin C; Sydney Medical School, The University of Sydney, Camperdown, NSW, Australia.
  • Farah CS; The Woolcock Emphysema Centre, Woolcock Institute of Medical Research, Glebe, NSW, Australia.
  • Bertolin A; Sydney Medical School, The University of Sydney, Camperdown, NSW, Australia.
  • Chapman DG; The Woolcock Emphysema Centre, Woolcock Institute of Medical Research, Glebe, NSW, Australia.
  • Berend N; Sydney Medical School, The University of Sydney, Camperdown, NSW, Australia.
  • Salome CM; Department of Respiratory Medicine, Concord Hospital, Concord, NSW, Australia.
  • King GG; The Woolcock Emphysema Centre, Woolcock Institute of Medical Research, Glebe, NSW, Australia.
Respirology ; 23(5): 512-518, 2018 05.
Article em En | MEDLINE | ID: mdl-29141272
ABSTRACT
BACKGROUND AND

OBJECTIVE:

Smokers develop respiratory symptoms and peripheral airway dysfunction even when spirometry is preserved. Multiple breath nitrogen washout (MBNW) and impulse oscillometry system (IOS) are potentially useful measures of peripheral airway function but they have not been compared in such subjects. We hypothesized that MBNW and IOS are jointly abnormal in smokers with normal spirometry and that these abnormalities relate to respiratory symptoms.

METHODS:

Eighty smokers with normal spirometry completed a symptom questionnaire, had ventilation heterogeneity in diffusion (Sacin) and convection-dependent (Scond) airways and trapped gas volume at functional residual capacity as a percentage of vital capacity (%VtrFRC/VC) measured by MBNW. Respiratory resistance and reactance at 5 and 20 Hz were measured using IOS.

RESULTS:

Respiratory symptoms were reported in 55 (68%) subjects. Forty (50%) subjects had at least one abnormal MBNW parameter, predominantly in Sacin. Forty-one (51%) subjects had at least one abnormal IOS parameter, predominantly in resistance. Sixty-one (76%) subjects had an abnormality in either MBNW or IOS. Chronic bronchitis symptoms were associated with an increased Scond, while wheeze was associated with lower spirometry and an increased resistance. Abnormalities in MBNW and IOS parameters were unrelated to each other.

CONCLUSIONS:

Respiratory symptoms and peripheral airway dysfunction are common in smokers with normal spirometry. Symptoms of chronic bronchitis related to conductive airway abnormalities, while wheeze was related to spirometry and IOS. The clinical significance of abnormalities in peripheral airway function in smokers remains undetermined.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fumar / Bronquite Crônica / Pulmão Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fumar / Bronquite Crônica / Pulmão Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2018 Tipo de documento: Article