Precise measurement of inner diameter of mono-capillary optic using X-ray imaging technique.
Kwon, Soonmu; Lim, Jae Hong; Namba, Yoshiharu; Chon, Kwon Su.
Afiliação
  • Kwon S; Department of Radiological Science, Catholic University of Daegu, Hayang-ro, Hayang, Gyeongsan, Gyeongbuk, Republic of Korea.
  • Lim JH; Department of Radiologic Technology, Daegu Health College, Youngsong-ro, Buk-gu, Daegu, Republic of Korea.
  • Namba Y; Pohng Accelerator Laboratory, Nam-gu, Pohng, Gyeongbuk, Republic of Korea.
  • Chon KS; Department of Mechanical Engineering, Chubu University, Matsumoto-cho, Kasugai, Aichi, Japan.
J Xray Sci Technol ; 26(2): 263-272, 2018.
Article em En | MEDLINE | ID: mdl-29154311
ABSTRACT

BACKGROUND:

Mono-capillary optics have been applied to increase the performance of X-ray instruments. However, performance of a mono-capillary optic strongly depends on the shape accuracy, which is determined by the diameters of the inner hollow of the capillary along the axial direction.

OBJECTIVE:

To precisely determine the inner diameter of the capillary optic used in X-ray imaging technique, which aims to replace the conventional method using a visible microscope.

METHODS:

High spatial resolution X-ray images of the mono-capillary optic were obtained by a synchrotron radiation beamline. The inner diameter of the mono-capillary optic was measured and analyzed by the pixel values of the X-ray image.

RESULT:

Edge enhancement effect was quite useful in determining the inner diameter, and the accuracy of the diameter determination was less than 1.32 µm. Many images obtained by scanning the mono-capillary optic along the axial direction were combined, and the axial profile, consisting of diameters along the axial direction, was obtained from the combined image. The X-ray imaging method could provide an accurate measurement with slope error of±19 µrad.

CONCLUSIONS:

Applying X-ray imaging technique to determine the inner diameter of a mono-capillary optic can contribute to increasing fabrication accuracy of the mono-capillary optic through a feedback process between the fabrication and measurement of its diameter.