OBJECTIVES:
To compare the diagnostic accuracy between low-kilovolt peak (kVp) (≤ 100) and high-kVp (> 100) third-generation dual-source coronary CT angiography (CCTA) using a kVp-tailored contrast media injection protocol.METHODS:
One hundred twenty patients (mean age = 62.6 years, BMI = 29.0 kg/m2) who underwent catheter angiography and CCTA with automated kVp selection were separated into two cohorts (each n = 60, mean kVp = 84 and 117). Contrast media dose was tailored to the kVp level 70 = 40 ml, 80 = 50 ml, 90 = 60 ml, 100 = 70 ml, 110 = 80 ml, and 120 = 90 ml. Contrast-to-noise ratio (CNR) was measured. Two observers evaluated image quality and the presence of significant coronary stenosis (> 50% luminal narrowing).RESULTS:
Diagnostic accuracy (sensitivity/specificity) with ≤ 100 vs. > 100 kVp CCTA was comparable per patient = 93.9/92.6% vs. 90.9/92.6%, per vessel = 91.5/97.8% vs. 94.0/96.8%, and per segment = 90.0/96.7% vs. 90.7/95.2% (all P > 0.64). CNR was similar (P > 0.18) in the low-kVp vs. high-kVp group (12.0 vs. 11.1), as ws subjective image quality (P = 0.38). Contrast media requirements were reduced by 38.1% in the low- vs. high-kVp cohort (53.6 vs. 86.6 ml, P < 0.001) and radiation dose by 59.6% (4.3 vs. 10.6 mSv, P < 0.001).CONCLUSIONS:
Automated tube voltage selection with a tailored contrast media injection protocol allows CCTA to be performed at ≤ 100 kVp with substantial dose reductions and equivalent diagnostic accuracy for coronary stenosis detection compared to acquisitions at > 100 kVp. KEY POINTS ⢠Low-kVp coronary CT angiography (CCTA) enables reduced contrast and radiation dose. ⢠Diagnostic accuracy is comparable between ≤ 100 and > 100 kVp CCTA. ⢠Image quality is similar for low- and high-kVp CCTA. ⢠Low-kVp image acquisition is facilitated by automated tube voltage selection. ⢠Tailoring contrast injection protocols to the automatically selected kVp-level is feasible.Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Angiografia Coronária
/
Meios de Contraste
/
Estenose Coronária
/
Angiografia por Tomografia Computadorizada
Tipo de estudo:
Diagnostic_studies
/
Guideline
/
Observational_studies
/
Prognostic_studies
Limite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Ano de publicação:
2018
Tipo de documento:
Article