Your browser doesn't support javascript.
loading
Imaging-based predictors of permanent pacemaker implantation after transcatheter aortic valve replacement.
Routh, Jared M; Joseph, Lee; Marthaler, Brodie R; Bhave, Prashant D.
Afiliação
  • Routh JM; University of Iowa Hospitals and Clinics, Iowa City, IA, USA.
  • Joseph L; University of Iowa Hospitals and Clinics, Iowa City, IA, USA.
  • Marthaler BR; University of Iowa Hospitals and Clinics, Iowa City, IA, USA.
  • Bhave PD; Wake Forest University Health Sciences Center, Winston-Salem, NC, USA.
Pacing Clin Electrophysiol ; 41(1): 81-86, 2018 01.
Article em En | MEDLINE | ID: mdl-29205396
BACKGROUND: Cardiac conduction abnormalities requiring permanent pacemaker (PPM) implantation are major complications of transcatheter aortic valve replacement (TAVR). We aimed to investigate whether the relationship between prosthetic valve size and cardiac-gated computed tomography (CT)-based aortic root complex measurements can aid in recognizing patients at risk for PPM implantation post-TAVR. METHODS: We included 83 of 114 consecutive patients who underwent TAVR with the Edwards Sapien valve (Edwards Lifesciences, Irving, CA, USA) at our institution. We excluded patients with preexisting PPM, patients who required conversion to an open surgical procedure, and patients without CT data. We assessed the significance of various potential predictors of PPM placement post-TAVR. RESULTS: Following TAVR, eight patients (9.6%) required PPM. Prosthetic valve to sinus of Valsalva (SOV) index was significantly higher in those patients requiring a PPM post-TAVR (84.1 ± 9.3 vs 76.8 ± 7.1, P  =  0.009). CONCLUSIONS: The prosthetic valve size to diameter of SOV index was identified as a novel predictor of PPM implantation after TAVR.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Insuficiência da Valva Aórtica / Marca-Passo Artificial / Próteses Valvulares Cardíacas / Tomografia Computadorizada por Raios X / Técnicas de Imagem de Sincronização Cardíaca / Substituição da Valva Aórtica Transcateter Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged80 / Female / Humans / Male Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Insuficiência da Valva Aórtica / Marca-Passo Artificial / Próteses Valvulares Cardíacas / Tomografia Computadorizada por Raios X / Técnicas de Imagem de Sincronização Cardíaca / Substituição da Valva Aórtica Transcateter Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged80 / Female / Humans / Male Idioma: En Ano de publicação: 2018 Tipo de documento: Article