Double layered stents for carotid angioplasty: A meta-analysis of available clinical data.
Sannino, Anna; Giugliano, Giuseppe; Toscano, Evelina; Schiattarella, Gabriele G; Franzone, Anna; Tesorio, Tullio; Trimarco, Bruno; Esposito, Giovanni; Stabile, Eugenio.
Afiliação
  • Sannino A; Division of Cardiology, University of Naples "Federico II", Naples, Italy.
  • Giugliano G; Department of Advanced Biomedical Sciences, University of Naples "Federico II", Naples, Italy.
  • Toscano E; Division of Cardiology, University of Naples "Federico II", Naples, Italy.
  • Schiattarella GG; Department of Advanced Biomedical Sciences, University of Naples "Federico II", Naples, Italy.
  • Franzone A; Division of Cardiology, University of Naples "Federico II", Naples, Italy.
  • Tesorio T; Department of Advanced Biomedical Sciences, University of Naples "Federico II", Naples, Italy.
  • Trimarco B; Division of Cardiology, University of Naples "Federico II", Naples, Italy.
  • Esposito G; Department of Advanced Biomedical Sciences, University of Naples "Federico II", Naples, Italy.
  • Stabile E; Division of Cardiology, University of Naples "Federico II", Naples, Italy.
Catheter Cardiovasc Interv ; 91(4): 751-757, 2018 03 01.
Article em En | MEDLINE | ID: mdl-29239099
ABSTRACT

OBJECTIVES:

The objective of this meta-analysis is to evaluate clinical efficacy of double layered mesh covered carotid stent systems in the clinical practice.

BACKGROUND:

The need for an increase plaque coverage to decrease the risk of debris dislodgement through the stent struts, following carotid artery stenting (CAS), has brought to the design of a new generation of double layered carotid stents. Several small sized clinical studies evaluating two different devices have been recently published, unfortunately these are not sufficiently powered to test for device related and clinical endpoints and no comparison, between the two available devices, has been reported yet.

METHODS:

Ten studies, enrolling 635 patients, were included in the present meta-analysis. Our study analyzed a composite endpoint of 30-day stroke and death and the occurrence of procedural unsuccess after CAS with the use of two different double layered carotid stent systems.

RESULTS:

Thirty-day stroke and death rate was quite low (patients 635, event rate 0.02, 95% CI 0.01-0.04, P < 0.0001). The incidence of procedural unsuccess with these devices was relatively low (patients 635, event rate 0.03, 95% CI 0.01-0.08, P < 0.0001). When a subgroup analysis was performed, according to the specific subtype of carotid stent, no differences in the occurrence of 30-day death and stroke rate and procedural unsuccess were observed (P = 0.979).

CONCLUSIONS:

This meta-analysis suggests that dual layered carotid stents could be safely used for the treatment of extracranial carotid artery stenosis, with a relatively low rate of procedural unsuccess, and allow achieving a quite low rate of postprocedural adverse events.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Stents / Estenose das Carótidas / Angioplastia Tipo de estudo: Etiology_studies / Incidence_studies / Prognostic_studies / Risk_factors_studies / Systematic_reviews Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Stents / Estenose das Carótidas / Angioplastia Tipo de estudo: Etiology_studies / Incidence_studies / Prognostic_studies / Risk_factors_studies / Systematic_reviews Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2018 Tipo de documento: Article