Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening patients with imported malaria in a non-endemic setting.
Ponce, Camille; Kaczorowski, Flora; Perpoint, Thomas; Miailhes, Patrick; Sigal, Alain; Javouhey, Etienne; Gillet, Yves; Jacquin, Laurent; Douplat, Marion; Tazarourte, Karim; Potinet, Véronique; Simon, Bruno; Lavoignat, Adeline; Bonnot, Guillaume; Sow, Fatimata; Bienvenu, Anne-Lise; Picot, Stéphane.
Afiliação
  • Ponce C; Institute of Parasitology and Medical Mycology, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France.
  • Kaczorowski F; Institute of Parasitology and Medical Mycology, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France.
  • Perpoint T; Service des Maladies Infectieuses et Tropicales, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France.
  • Miailhes P; Service des Maladies Infectieuses et Tropicales, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France.
  • Sigal A; Service d'accueil des Urgences, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France.
  • Javouhey E; Service d'accueil des Urgences Pédiatriques, Hôpital Femme-Mère-Enfant, Hospices Civils de Lyon, 69677 Bron, France.
  • Gillet Y; Service d'accueil des Urgences Pédiatriques, Hôpital Femme-Mère-Enfant, Hospices Civils de Lyon, 69677 Bron, France.
  • Jacquin L; Service d'accueil des urgences, Hôpital Edouard Herriot, Hospices Civils de Lyon, 69003 Lyon, France.
  • Douplat M; Service d'accueil des urgences, Hôpital Lyon Sud, Hospices Civils de Lyon, Hôpital Lyon Sud, 69310 Pierre-Bénite, France.
  • Tazarourte K; Service des urgences/SAMU 69, Hospices Civils de Lyon, Lyon, 69003, France - Univ. Lyon, Université Claude Bernard Lyon 1, HESPER EA 7425, 69008 Lyon, France.
  • Potinet V; Service d'accueil des urgences, Hôpital Lyon Sud, Hospices Civils de Lyon, Hôpital Lyon Sud, 69310 Pierre-Bénite, France.
  • Simon B; Institute of Parasitology and Medical Mycology, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France.
  • Lavoignat A; Malaria Research Unit, SMITh, ICBMS, UMR 5246 CNRS-INSA-CPE-University Lyon1, 69100 Villeurbanne, France.
  • Bonnot G; Malaria Research Unit, SMITh, ICBMS, UMR 5246 CNRS-INSA-CPE-University Lyon1, 69100 Villeurbanne, France.
  • Sow F; Malaria Research Unit, SMITh, ICBMS, UMR 5246 CNRS-INSA-CPE-University Lyon1, 69100 Villeurbanne, France.
  • Bienvenu AL; Malaria Research Unit, SMITh, ICBMS, UMR 5246 CNRS-INSA-CPE-University Lyon1, 69100 Villeurbanne, France - Laboratoire d'Hématologie, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France.
  • Picot S; Institute of Parasitology and Medical Mycology, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France - Malaria Research Unit, SMITh, ICBMS, UMR 5246 CNRS-INSA-CPE-University Lyon1, 69100 Villeurbanne, France.
Parasite ; 24: 53, 2017.
Article em En | MEDLINE | ID: mdl-29251261
ABSTRACT

BACKGROUND:

Sensitive and easy-to-perform methods for the diagnosis of malaria are not yet available. Improving the limit of detection and following the requirements for certification are issues to be addressed in both endemic and non-endemic settings. The aim of this study was to test whether loop-mediated isothermal amplification of DNA (LAMP) may be an alternative to microscopy or real-time PCR for the screening of imported malaria cases in non-endemic area.

RESULTS:

310 blood samples associated with 829 suspected cases of imported malaria were tested during a one year period. Microscopy (thin and thick stained blood slides, reference standard) was used for the diagnosis. Real-time PCR was used as a standard of truth, and LAMP (Meridian Malaria Plus) was used as an index test in a prospective study conducted following the Standards for Reporting Diagnosis Accuracy Studies. In the 83 positive samples, species identification was P. falciparum (n = 66), P. ovale (n = 9), P. vivax (n = 3) P. malariae (n = 3) and 2 co-infections with P. falciparum + P.malariae. Using LAMP methods, 93 samples gave positive results, including 4 false-positives. Sensitivity, specificity, positive predictive value and negative predictive value for LAMP tests were 100%, 98.13%, 95.51%, and 100% compared to PCR.

CONCLUSION:

High negative predictive value, and limit of detection suggest that LAMP can be used for screening of imported malaria cases in non-endemic countries when expert microscopists are not immediately available. However, the rare occurrence of non-valid results and the need for species identification and quantification of positive samples preclude the use of LAMP as a single reference method.