Determination of PMMA Residues on a Chemical-Vapor-Deposited Monolayer of Graphene by Neutron Reflection and Atomic Force Microscopy.
Li, Ruiheng; Li, Zongyi; Pambou, Elias; Gutfreund, Philipp; Waigh, Thomas A; Webster, John R P; Lu, Jian R.
Afiliação
  • Li R; Biological Physics Group, School of Physics and Astronomy, University of Manchester , Oxford Road, Manchester M13 9PL, U.K.
  • Li Z; Biological Physics Group, School of Physics and Astronomy, University of Manchester , Oxford Road, Manchester M13 9PL, U.K.
  • Pambou E; Biological Physics Group, School of Physics and Astronomy, University of Manchester , Oxford Road, Manchester M13 9PL, U.K.
  • Gutfreund P; Institut Laue-Langevin , 71 Avenue des Martyrs, 38000 Grenoble, France.
  • Waigh TA; Biological Physics Group, School of Physics and Astronomy, University of Manchester , Oxford Road, Manchester M13 9PL, U.K.
  • Webster JRP; STFC ISIS Facility, Rutherford Appleton Laboratory , Didcot OX11 0QX, U.K.
  • Lu JR; Biological Physics Group, School of Physics and Astronomy, University of Manchester , Oxford Road, Manchester M13 9PL, U.K.
Langmuir ; 34(5): 1827-1833, 2018 02 06.
Article em En | MEDLINE | ID: mdl-29303580
ABSTRACT
Chemical vapor deposition (CVD) is now a well-established method for creating monolayer graphene films. In this method, poly(methyl methacrylate) (PMMA) films are often coated onto monolayer graphene films to make them mechanically robust enough for transfer and further handling. However, it is found that PMMA is hard to remove entirely, and any residual polymers remaining can affect graphene's properties. We demonstrate here a method to determine the amount of PMMA remaining on the graphene sheet fabricated from CVD by a combined study of Raman scattering, atomic force microscopy, and neutron reflection. Neutron reflectivity is a powerful technique which is particularly sensitive to any interfacial structure, so it is able to investigate the density profile of the residual PMMA in the direction perpendicular to the graphene film surface. After the standard process of PMMA removal by acetone-IPA cleaning, we found that the remaining PMMA film could be represented as a two-layer model an inner layer with a thickness of 17 Å and a roughness of 1 Å mixed with graphene and an outer diffuse layer with an average thickness of 31 Å and a roughness of 4 Å well mixed with water. On the basis of this model analysis, it was demonstrated that the remaining PMMA still occupied a significant fraction of the graphene film surface.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article