Your browser doesn't support javascript.
loading
Late results of right ventricular outflow tract reconstruction with a bicuspid expanded polytetrafluoroethylene valved conduit.
Choi, Kwang Ho; Sung, Si Chan; Kim, Hyungtae; Lee, Hyoung Doo; Kim, Geena; Ko, Hoon.
Afiliação
  • Choi KH; Department of Thoracic and Cardiovascular Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Gyeongsangnam-do, Republic of Korea.
  • Sung SC; Department of Thoracic and Cardiovascular Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Gyeongsangnam-do, Republic of Korea.
  • Kim H; Department of Thoracic and Cardiovascular Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Gyeongsangnam-do, Republic of Korea.
  • Lee HD; Department of Pediatric Cardiology, Pusan National University Yangsan Hospital, Yangsan-si, Gyeongsangnam-do, Republic of Korea.
  • Kim G; Department of Pediatric Cardiology, Pusan National University Yangsan Hospital, Yangsan-si, Gyeongsangnam-do, Republic of Korea.
  • Ko H; Department of Pediatric Cardiology, Pusan National University Yangsan Hospital, Yangsan-si, Gyeongsangnam-do, Republic of Korea.
J Card Surg ; 33(1): 36-40, 2018 Jan.
Article em En | MEDLINE | ID: mdl-29314335
BACKGROUND AND AIM TO READ: We report the results of a bicuspid expanded polytetrafluoroethylene (ePTFE) valved conduit used for right ventricular outflow tract reconstruction (RVOTR). METHODS: Between November 2005 and February 2009, 12 conduits were used for RVOTR. The mean age and weight of patients were 43.5 ± 46.4 months and 13.4 ± 8.6 kg. The main diagnosis was tetralogy of Fallot with pulmonary atresia in eight patients. The most common conduit size was 18 mm. The mean follow-up was 88.0 ± 35.9 months. RESULTS: There were no operative and late mortalities. At discharge, the mean peak systolic pressure gradient across the RVOT was 14.1 ± 11.3 mmHg. There was no conduit valve regurgitation in nine patients. At the latest echocardiography (mean follow-up: 84.3 ± 35.5 months), the mean peak systolic pressure gradient across the RVOT was 59.7 ± 20.2 mmHg, and there was no conduit valve regurgitation in six patients. Freedom from conduit malfunction was 100% and 83.3%, at 1 and 8 years, respectively. Two conduits were explanted due to sternal compression and four from conduit malfunction. Freedom from explantation was 83.3% and 74.2% at 2 and 8 years, respectively. CONCLUSIONS: ePTFE bicuspid valved conduit has good late function in terms of valve regurgitation, but the pressure gradient across the conduit increases with time, which is the main cause of conduit failure and explantation.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Politetrafluoretileno / Procedimentos Cirúrgicos Cardiovasculares / Obstrução do Fluxo Ventricular Externo / Procedimentos de Cirurgia Plástica Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Child, preschool / Humans / Infant / Newborn Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Politetrafluoretileno / Procedimentos Cirúrgicos Cardiovasculares / Obstrução do Fluxo Ventricular Externo / Procedimentos de Cirurgia Plástica Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Child, preschool / Humans / Infant / Newborn Idioma: En Ano de publicação: 2018 Tipo de documento: Article