Sensing performance, safety, and patient acceptability of long-dipole cardiac monitor: An innovative axillary insertion.
Bisignani, Giovanni; De Bonis, Silvana; Bisignani, Antonio; Mancuso, Luigi; Giacopelli, Daniele.
Afiliação
  • Bisignani G; Department of Cardiology, Ospedale, Castrovillari, Cosenza, Italy.
  • De Bonis S; Department of Cardiology, Ospedale, Castrovillari, Cosenza, Italy.
  • Bisignani A; Institute of Cardiology, Catholic University of the Sacred Heart, Rome, Italy.
  • Mancuso L; BIOTRONIK Italia S.p.A., Milano, Italy.
  • Giacopelli D; BIOTRONIK Italia S.p.A., Milano, Italy.
Pacing Clin Electrophysiol ; 41(3): 277-283, 2018 03.
Article em En | MEDLINE | ID: mdl-29341174
BACKGROUND: The recommended location for implantable cardiac monitor (ICM) insertion is the left pectoral region. We tested whether an innovative left axillary implantation approach could be applicable for a new ICM, characterized by a long sensing dipole. METHODS: We considered a series of 55 patients consecutively implanted with a long-dipole ICM (BioMonitor 2); the first 30 subjects underwent prepectoral location insertion, while the subsequent 25 received the ICM in the axillary region. Sensing performances collected at 1-month follow-up were compared between the two groups. During the visit, each patient was also asked to fill in a brief questionnaire to assess patient acceptability of the device. RESULTS: All patients had a successful insertion of ICM. Mean R-wave amplitude was 0.87 ± 0.44 mV in the prepectoral group and 1.00 ± 0.45 mV in the axillary one, without any significant difference. The percentage of patients with visible P wave was also comparable between the two approaches (65.5% vs 68.2%, P = 0.84). None of the patients reported device-related issues or discomfort, and ICM was generally well accepted and tolerated by all the involved patients. CONCLUSION: Axillary insertion may represent a valid alternative to the standard one for long-dipole ICM technology providing not only patient acceptability but also high-quality sensing performances.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Axila / Aceitação pelo Paciente de Cuidados de Saúde / Eletrocardiografia Ambulatorial / Implantação de Prótese / Segurança do Paciente Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Axila / Aceitação pelo Paciente de Cuidados de Saúde / Eletrocardiografia Ambulatorial / Implantação de Prótese / Segurança do Paciente Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article