Non-contrast enhanced 4D intracranial MR angiography based on pseudo-continuous arterial spin labeling with the keyhole and view-sharing technique.
Obara, Makoto; Togao, Osamu; Beck, Gabriele M; Shibukawa, Shuhei; Okuaki, Tomoyuki; Yoneyama, Masami; Nakamura, Masanobu; Honda, Hiroshi; Van Cauteren, Marc.
Afiliação
  • Obara M; Philips Electronics Japan Ltd., Healthcare, Shinagawa, Tokyo, Japan.
  • Togao O; Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
  • Beck GM; Philips Healthcare, Best, The Netherlands.
  • Shibukawa S; Department of Radiology, Tokai University Hospital, Isehara, Kanagawa, Japan.
  • Okuaki T; Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan.
  • Yoneyama M; Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan.
  • Nakamura M; Philips Healthcare, Asia Pacific, Shinagawa, Tokyo, Japan.
  • Honda H; Philips Electronics Japan Ltd., Healthcare, Shinagawa, Tokyo, Japan.
  • Van Cauteren M; Philips Electronics Japan Ltd., Healthcare, Shinagawa, Tokyo, Japan.
Magn Reson Med ; 80(2): 719-725, 2018 08.
Article em En | MEDLINE | ID: mdl-29369424
ABSTRACT

PURPOSE:

4D dynamic MR angiography (4D-MRA) using pseudo-continuous arterial spin labeling (pCASL), combined with Keyhole and View-sharing (4D-PACK) for scan acceleration, is introduced. Its validity for arterial inflow dynamics visualization was investigated through comparison with 4D-pCASL and contrast inherent inflow enhanced multiphase angiography (CINEMA).

METHODS:

Six healthy volunteers were included in the study. The arterial transit time (ATT) in 4D-PACK was measured at multiple regions in middle cerebral artery (MCA), and Pearson's correlation coefficient with ATT in 4D-pCASL was calculated. The contrast-to-noise ratio (CNR) in 4D-PACK was measured in four MCA segments and compared with that in 4D-pCASL and CINEMA. Arterial visualization in 4D-PACK was assessed qualitatively in patients with moyamoya disease and arteriovenous malformation by comparing with CINEMA.

RESULTS:

4D-PACK achieved a 36% scan time reduction compared with 4D-pCASL. The correlation coefficient for ATT measured by 4D-pCASL and 4D-PACK was greater than 0.96. The CNR was significantly higher using 4D-PACK compared with CINEMA in the M4 segment (P < 0.01). In patient examinations, the flow in the collateral artery or draining vein was better visualized in 4D-PACK compared with CINEMA.

CONCLUSION:

4D-PACK accelerates 4D-pCASL, shows similar inflow dynamics as 4D-pCASL and shows better peripheral visualization compared with CINEMA. Magn Reson Med 80719-725, 2018. © 2018 International Society for Magnetic Resonance in Medicine.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artérias Cerebrais / Angiografia por Ressonância Magnética / Imageamento Tridimensional Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2018 Tipo de documento: Article