Your browser doesn't support javascript.
loading
Fitness and retentive force of cobalt-chromium alloy clasps fabricated with repeated laser sintering and milling.
Torii, Mana; Nakata, Toyoki; Takahashi, Kazuya; Kawamura, Noboru; Shimpo, Hidemasa; Ohkubo, Chikahiro.
Afiliação
  • Torii M; Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine, Yokohama, Japan. Electronic address: torii-mana@tsurumi-u.ac.jp.
  • Nakata T; Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine, Yokohama, Japan.
  • Takahashi K; Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine, Yokohama, Japan.
  • Kawamura N; Department of Technician Training Institute, Tsurumi University Dental Hospital, Yokohama, Japan.
  • Shimpo H; Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine, Yokohama, Japan.
  • Ohkubo C; Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine, Yokohama, Japan.
J Prosthodont Res ; 62(3): 342-346, 2018 Jul.
Article em En | MEDLINE | ID: mdl-29428170
ABSTRACT

PURPOSE:

With computer-aided design and computer-aided manufacturing (CAD/CAM), the study was conducted to create a removable partial denture (RPD) framework using repeated laser sintering rather than milling and casting techniques. This study experimentally evaluated the CAM clasp and compared it to a conventional cast clasp.

METHODS:

After the tooth die was scanned, an Akers clasp was designed using CAD with and without 50µm of digital relief on the occlusal surface of the tooth die. Cobalt-chromium (Co-Cr) alloy clasps were fabricated using repeated laser sintering (RLS) and milling as one process simultaneously (hybrid manufacturing; HM). The surface roughness of the rest region, gap distances between clasp and tooth die, initial retentive forces, and changes of retentive forces up to 10,000 insertion/removal cycles were measured before and after heat treatment. The HM clasp was compared to the cast clasp and the clasp made by repeated laser sintering only without a milling process.

RESULTS:

The HM clasp surface was smoother than those of cast and RLS clasps. With the digital relief, the fitness accuracy of the HM clasp improved. The retentive forces of the HM clasps with relief and after heat treatment were significantly greater than for the cast clasp. HM clasps demonstrated a constant or slight decrease of retention up to 10,000 cycles.

CONCLUSIONS:

HM clasp exhibited better fitness accuracy and retentive forces. The possibility of clinically using HM clasps as well as conventional cast clasps can be suggested.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Teste de Materiais / Ligas de Cromo / Retenção de Dentadura / Grampos Dentários / Planejamento de Prótese Dentária / Desenho Assistido por Computador / Análise do Estresse Dentário / Prótese Parcial Removível / Lasers Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Teste de Materiais / Ligas de Cromo / Retenção de Dentadura / Grampos Dentários / Planejamento de Prótese Dentária / Desenho Assistido por Computador / Análise do Estresse Dentário / Prótese Parcial Removível / Lasers Idioma: En Ano de publicação: 2018 Tipo de documento: Article