Your browser doesn't support javascript.
loading
Parameters influencing hand grip strength measured with the manugraphy system.
Wichelhaus, Alice; Harms, Christoph; Neumann, Julia; Ziegler, Steffen; Kundt, Günther; Prommersberger, Karl Josef; Mittlmeier, Thomas; Mühldorfer-Fodor, Marion.
Afiliação
  • Wichelhaus A; Clinic for Trauma, Hand and Reconstructive Surgery, University of Rostock Medical School, Schillingallee 35, 18057, Rostock, Germany. alice.wichelhaus@med.uni-rostock.de.
  • Harms C; Clinic for Trauma, Hand and Reconstructive Surgery, University of Rostock Medical School, Schillingallee 35, 18057, Rostock, Germany.
  • Neumann J; Clinic for Trauma, Hand and Reconstructive Surgery, University of Rostock Medical School, Schillingallee 35, 18057, Rostock, Germany.
  • Ziegler S; Clinic for Hand Surgery, Rhön Klinikum AG, Salzburger Leite 1, 97616, Bad Neustadt an der Saale, Germany.
  • Kundt G; Institute for Biostatistics and Informatics in Medicine and Ageing Research, University of Rostock, Ernst-Heydemann Str. 8, 18057, Rostock, Germany.
  • Prommersberger KJ; Clinic for Hand Surgery, Rhön Klinikum AG, Salzburger Leite 1, 97616, Bad Neustadt an der Saale, Germany.
  • Mittlmeier T; Clinic for Trauma, Hand and Reconstructive Surgery, University of Rostock Medical School, Schillingallee 35, 18057, Rostock, Germany.
  • Mühldorfer-Fodor M; Clinic for Hand Surgery, Rhön Klinikum AG, Salzburger Leite 1, 97616, Bad Neustadt an der Saale, Germany.
BMC Musculoskelet Disord ; 19(1): 54, 2018 02 14.
Article em En | MEDLINE | ID: mdl-29444676
ABSTRACT

BACKGROUND:

This study aimed to determine whether sex, hand length and the individual training status affect hand strength and whether these measurements differ if they are recorded using the Jamar dynamometer or a new cylindrical measuring system.

METHODS:

For this purpose, 152 healthy adults were examined using a new manugraphy measuring system (novel, Munich, Germany) comprising two measuring cylinders of different sizes and a Jamar electronic dynamometer with two grip positions corresponding approximately to the sizes of the cylinders. A descriptive analysis was performed as well as a correlation analysis using the Pearson correlation coefficient. To prepare predictive models, multiple linear regression analyses were carried out to determine factors that influence the force and p ≤ 0.05 was considered statistically significant.

RESULTS:

A significant difference in the maximum and mean strength was observed that is dependent on sex, with men stronger than women, in line with expectations, and hand length, with small hands able to exert less force than large hands. No consistent increase in strength could be attributed to repetitive manual loads applied either at work or in leisure activities.

CONCLUSIONS:

Both measurement techniques yielded similar results, suggesting that manugraphy is well suited for clinical research purposes because it not only takes measurements that are just as reproducible and valid as the conventional measurement technique but in doing so measures not just the total strength of a hand but also enables more precise comparisons of isolated hand regions applying dynamic measurements.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Força da Mão / Dinamômetro de Força Muscular Tipo de estudo: Guideline / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Força da Mão / Dinamômetro de Força Muscular Tipo de estudo: Guideline / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article