Your browser doesn't support javascript.
loading
Vision-Related Quality of Life Associated with Unilateral and Bilateral Ocular Conditions.
Brown, Gary C; Brown, Melissa M; Stein, Joshua D; Smiddy, William E.
Afiliação
  • Brown GC; Center for Value-Based Medicine, Hilton Head, South Carolina; Wills Eye Hospital, Jefferson Medical University, Philadelphia, Pennsylvania; The Eye Research Institute, Philadelphia, Pennsylvania; Department of Ophthalmology, Emory University School of Medicine, Atlanta, Georgia. Electronic address:
  • Brown MM; Center for Value-Based Medicine, Hilton Head, South Carolina; Wills Eye Hospital, Jefferson Medical University, Philadelphia, Pennsylvania; The Eye Research Institute, Philadelphia, Pennsylvania; Department of Ophthalmology, Emory University School of Medicine, Atlanta, Georgia.
  • Stein JD; Glaucoma Service, University of Michigan Kellogg Eye Center, University of Michigan School of Medicine, Ann Arbor, Michigan.
  • Smiddy WE; Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami School of Medicine, Miami, Florida.
Ophthalmology ; 125(7): 965-971, 2018 07.
Article em En | MEDLINE | ID: mdl-29477690
PURPOSE: To present ophthalmic patient time-tradeoff vision utilities for quantifying vision-related quality-of-life when the fellow eye still has good vision. These utilities are important for performing reliable cost-utility analyses. DESIGN: Consecutive time-tradeoff vision utilities were obtained from ophthalmic patients with good vision (20/20-20/25) in one eye and vision ranging from 20/20 to no light perception in the fellow eye over a 15-year period from 2000 through 2014. PARTICIPANTS: Five hundred eighty-six ophthalmic participant interviews from Wills Eye Hospital, New York Eye and Ear Hospital, and ophthalmology office practices in Pennsylvania and New Jersey. METHODS: Participants underwent a full ophthalmic examination, after which time-tradeoff vision utilities were obtained by personal interview by the authors using a standardized, validated instrument. MAIN OUTCOME MEASURES: Time-tradeoff vision utilities. RESULTS: Mean time-tradeoff vision utilities were as follows in participants with good vision (20/20-20/25) in at least one eye and the following visions in the fellow eyes: no light perception, 0.79; counting fingers to light perception, 0.87; 20/200 to 20/400, 0.88; 20/60 to 20/100, 0.88; 20/30 to 20/50, 0.87; and 20/20 to 20/25, 0.94. CONCLUSIONS: In people with good vision (20/20-20/25) in one eye, the associated mean time-tradeoff vision utility is a remarkably consistent 0.87 to 0.88 when vision in the fellow eye ranges from 20/30 to light perception. Vision of 20/20 to 20/25 in the fellow eye results in a significantly higher associated utility of 0.94 (P < 0.01), whereas vision of no light perception in the fellow eye results in a significantly lower utility of 0.079 (P < 0.01). These utilities are important for calculating reliable patient value (quality-adjusted life-year) gains in ophthalmic cost-utility analysis populations in which there is unilateral and bilateral disease involvement.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Qualidade de Vida / Visão Ocular / Visão Binocular / Visão Monocular / Acuidade Visual / Análise Custo-Benefício / Oftalmopatias Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Qualidade de Vida / Visão Ocular / Visão Binocular / Visão Monocular / Acuidade Visual / Análise Custo-Benefício / Oftalmopatias Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article