Your browser doesn't support javascript.
loading
Evaluation of the flexural mechanical properties of various thermoplastic denture base polymers.
Lee, Hae-Hyoung; Lee, Jung-Hwan; Yang, Tae-Hyun; Kim, Yu-Jin; Kim, Si-Chul; Kim, Gyu-Ri; Kim, Hyung-Rae; Lee, Chung-Jae; Okubo, Chikahiro.
Afiliação
  • Lee HH; Department of Biomaterials Science, College of Dentistry, Dankook University.
  • Lee JH; Institute of Tissue Regeneration Engineering, Dankook University.
  • Yang TH; Institute of Tissue Regeneration Engineering, Dankook University.
  • Kim YJ; Department of Biomaterials Science, College of Dentistry, Dankook University.
  • Kim SC; Department of Biomaterials Science, College of Dentistry, Dankook University.
  • Kim GR; Department of Dental Technology, Chungbuk Health & Science University.
  • Kim HR; Department of Dental Laboratory, Gimcheon University.
  • Lee CJ; Department of Biomaterials Science, College of Dentistry, Dankook University.
  • Okubo C; Department of Dental Technology, Shinhan University.
Dent Mater J ; 37(6): 950-956, 2018 Nov 30.
Article em En | MEDLINE | ID: mdl-29515045
ABSTRACT
This study evaluated the flexural mechanical properties of various thermoplastic denture base polymers (six polyamides, four acrylic resins, polyester, polypropylene, and polycarbonate) by three different testing conditions; specimens were tested in water bath at 37°C (Wet/Water, by ISO 20795-1), or in ambient air (Wet/Air) after being immersed in distilled water for 50 h, or after desiccation for 7 days (Dry/Air). The mean ultimate flexural strength (UFS) and flexural modulus (FM) for most products ranged from 27 to 61 MPa and from 611 to 1,783 MPa respectively, which failed to meet the minimum requirements of the international standard, except for polycarbonate (89 and 2,245 MPa). The mean UFS and FM values were ranked Dry/Air>Wet/Air>Wet/Water (p<0.05). In conclusion, the flexural mechanical properties of denture base polymers varied with the products and were significantly affected by the testing medium (air or water) and specimen conditions (wet or dry).
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polímeros / Materiais Dentários / Bases de Dentadura Tipo de estudo: Evaluation_studies Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polímeros / Materiais Dentários / Bases de Dentadura Tipo de estudo: Evaluation_studies Idioma: En Ano de publicação: 2018 Tipo de documento: Article