Your browser doesn't support javascript.
loading
Improvement of human cell line activation test (h-CLAT) using short-time exposure methods for prevention of false-negative results.
Narita, Kazuto; Ishii, Yuuki; Vo, Phuc Thi Hong; Nakagawa, Fumiko; Ogata, Shinichi; Yamashita, Kunihiko; Kojima, Hajime; Itagaki, Hiroshi.
Afiliação
  • Narita K; Department of Chemical and Energy Engineering, Yokohama National University.
  • Ishii Y; Division of Risk Assessment, National Institute of Health Sciences.
  • Vo PTH; Department of Chemical and Energy Engineering, Yokohama National University.
  • Nakagawa F; Department of Chemical and Energy Engineering, Yokohama National University.
  • Ogata S; Department of Chemical and Energy Engineering, Yokohama National University.
  • Yamashita K; Department of Environment and Information Sciences, Yokohama National University.
  • Kojima H; Corporate Research Center, Daicel Corporation.
  • Itagaki H; Division of Risk Assessment, National Institute of Health Sciences.
J Toxicol Sci ; 43(3): 229-240, 2018.
Article em En | MEDLINE | ID: mdl-29540657
Recently, animal testing has been affected by increasing ethical, social, and political concerns regarding animal welfare. Several in vitro safety tests for evaluating skin sensitization, such as the human cell line activation test (h-CLAT), have been proposed. However, similar to other tests, the h-CLAT has produced false-negative results, including in tests for acid anhydride and water-insoluble chemicals. In a previous study, we demonstrated that the cause of false-negative results from phthalic anhydride was hydrolysis by an aqueous vehicle, with IL-8 release from THP-1 cells, and that short-time exposure to liquid paraffin (LP) dispersion medium could reduce false-negative results from acid anhydrides. In the present study, we modified the h-CLAT by applying this exposure method. We found that the modified h-CLAT is a promising method for reducing false-negative results obtained from acid anhydrides and chemicals with octanol-water partition coefficients (LogKow) greater than 3.5. Based on the outcomes from the present study, a combination of the original and the modified h-CLAT is suggested for reducing false-negative results. Notably, the combination method provided a sensitivity of 95% (overall chemicals) or 93% (chemicals with LogKow > 2.0), and an accuracy of 88% (overall chemicals) or 81% (chemicals with LogKow > 2.0). We found that the combined method is a promising evaluation scheme for reducing false-negative results seen in existing in vitro skin-sensitization tests. In the future, we expect a combination of original and modified h-CLAT to be applied in a newly developed in vitro test for evaluating skin sensitization.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Testes Cutâneos / Reações Falso-Negativas Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Testes Cutâneos / Reações Falso-Negativas Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article