Your browser doesn't support javascript.
loading
Diffuse optical monitoring of peripheral tissues during uncontrolled internal hemorrhage in a porcine model.
Vishwanath, Karthik; Gurjar, Rajan; Wolf, David; Riccardi, Suzannah; Duggan, Michael; King, David.
Afiliação
  • Vishwanath K; Department of Physics, Miami University, Oxford, OH 45056, USA.
  • Gurjar R; Affiliations of authors when experiments were conducted: Radiation Monitoring Devices Inc., 44 Hunt Street, Watertown, MA 02472, USA.
  • Wolf D; MIT Lincoln Laboratory, 244 Wood Street, Lexington, MA 02420, USA.
  • Riccardi S; Affiliations of authors when experiments were conducted: Radiation Monitoring Devices Inc., 44 Hunt Street, Watertown, MA 02472, USA.
  • Duggan M; Warner Babcock Institute for Green Chemistry, 100 Research Drive, Wilmington, MA 01887, USA.
  • King D; Affiliations of authors when experiments were conducted: Radiation Monitoring Devices Inc., 44 Hunt Street, Watertown, MA 02472, USA.
Biomed Opt Express ; 9(2): 569-580, 2018 Feb 01.
Article em En | MEDLINE | ID: mdl-29552394
ABSTRACT
Reliable, continuous and noninvasive blood flow and hemoglobin monitoring in trauma patients remains a critical, but generally unachieved goal. Two optical sensing methods - diffuse correlation spectroscopy (DCS) and diffuse reflectance spectroscopy (DRS) - are used to monitor and detect internal hemorrhage. Specifically, we investigate if cutaneous perfusion measurements acquired using DCS and DRS in peripheral (thighs and ear-lobe) tissues could detect severe hemorrhagic shock in a porcine model. Four animals underwent high-grade hepato-portal injury in a closed abdomen, to induce uncontrolled hemorrhage and were subsequently allowed to bleed for 10 minutes before fluid resuscitation. DRS and DCS measurements of cutaneous blood flow were acquired using fiber optical probes placed on the thigh and earlobe of the animals and were obtained repeatedly starting from 1 to 5 minutes pre-injury, up to several minutes post shock. Clear changes were observed in measured optical spectra across all animals at both sites. DCS-derived cutaneous blood flow decreased sharply during hemorrhage, while DRS-derived vascular saturation and hemoglobin paralleled cardiac output. All derived optical parameters had the steepest changes during the rapid initial hemorrhage unambiguously. This suggests that a combined DCS and DRS based device might provide an easy-to-use, non-invasive, internal-hemorrhage detection system that can be used across a wide array of clinical settings.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article