Comparison of in vivo vs. ex situ obtained material properties of sheep common carotid artery.
Smoljkic, Marija; Verbrugghe, Peter; Larsson, Matilda; Widman, Erik; Fehervary, Heleen; D'hooge, Jan; Vander Sloten, Jos; Famaey, Nele.
Afiliação
  • Smoljkic M; Biomechanics Section, Mechanical Engineering Department, KU Leuven, Leuven, Belgium.
  • Verbrugghe P; Clinical Cardiac Surgery, Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium.
  • Larsson M; School of Technology and Health, Department of Medical Engineering, KTH Royal Institute of Technology, Stockholm, Sweden; Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.
  • Widman E; School of Technology and Health, Department of Medical Engineering, KTH Royal Institute of Technology, Stockholm, Sweden; Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.
  • Fehervary H; Biomechanics Section, Mechanical Engineering Department, KU Leuven, Leuven, Belgium.
  • D'hooge J; Cardiovascular Imaging and Dynamics, Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium.
  • Vander Sloten J; Biomechanics Section, Mechanical Engineering Department, KU Leuven, Leuven, Belgium.
  • Famaey N; Clinical Cardiac Surgery, Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium. Electronic address: nele.famaey@kuleuven.be.
Med Eng Phys ; 55: 16-24, 2018 05.
Article em En | MEDLINE | ID: mdl-29580793
ABSTRACT
Patient-specific biomechanical modelling can improve preoperative surgical planning. This requires patient-specific geometry as well as patient-specific material properties as input. The latter are, however, still quite challenging to estimate in vivo. This study focuses on the estimation of the mechanical properties of the arterial wall. Firstly, in vivo pressure, diameter and thickness of the arterial wall were acquired for sheep common carotid arteries. Next, the animals were sacrificed and the tissue was stored for mechanical testing. Planar biaxial tests were performed to obtain experimental stress-stretch curves. Finally, parameters for the hyperelastic Mooney-Rivlin and Gasser-Ogden-Holzapfel (GOH) material model were estimated based on the in vivo obtained pressure-diameter data as well as on the ex situ experimental stress-stretch curves. Both material models were able to capture the in vivo behaviour of the tissue. However, in the ex situ case only the GOH model provided satisfactory results. When comparing different fitting approaches, in vivo vs. ex situ, each of them showed its own advantages and disadvantages. The in vivo approach estimates the properties of the tissue in its physiological state while the ex situ approach allows to apply different loadings to properly capture the anisotropy of the tissue. Both of them could be further enhanced by improving the estimation of the stress-free state, i.e. by adding residual circumferential stresses in vivo and by accounting for the flattening effect of the tested samples ex vivo. • Competing interests none declared • Word count 4716.
Assuntos