Your browser doesn't support javascript.
loading
Combined prospectively electrocardiography- and respiratory-triggered sequential cardiac computed tomography in free-breathing children: success rate and image quality.
Goo, Hyun Woo.
Afiliação
  • Goo HW; Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, South Korea. ghw68@hanmail.net.
Pediatr Radiol ; 48(7): 923-931, 2018 07.
Article em En | MEDLINE | ID: mdl-29589058
ABSTRACT

BACKGROUND:

Combined prospectively electrocardiography (ECG)- and respiratory-triggered sequential cardiac computed tomography (CT) has not been evaluated in free-breathing children.

OBJECTIVE:

To evaluate the success rate and image quality of combined prospectively ECG- and respiratory-triggered sequential cardiac CT in free-breathing children. MATERIALS AND

METHODS:

Image quality of combined prospectively ECG- and respiratory-triggered sequential cardiac CT in 870 children (≤5 years of age) was evaluated in terms of severe motion (maximal distance ≥2 mm) and band artifacts (maximal attenuation difference ≥100 Hounsfield units). The success rate of the scan mode was calculated. The causes of failed cases were assessed. Patient-related, radiation and image quality parameters were compared between success and failure groups.

RESULTS:

Severe motion artifacts were observed in 10.6% (92/870) of patients due to cardiac phase error in 17 (18.5%), patient motion in 12 (13.0%), and unknown causes in 63 (68.5%). Severe band artifacts were seen in 13.2% (115/870) of patients. Combined prospectively ECG- and respiratory-triggered sequential cardiac CT was successfully performed in 78.5% (683/870) of patients, while it failed in 21.5% (187/870). All the evaluated patient-related, radiation and image quality parameters were significantly different (P≤0.001) between success and failure groups except effective dose (P>0.05).

CONCLUSION:

Additional prospective respiratory triggering can reduce motion artifacts in prospectively ECG-triggered sequential cardiac CT in free-breathing children.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Técnicas de Imagem de Sincronização Cardíaca / Técnicas de Imagem de Sincronização Respiratória / Cardiopatias Congênitas Tipo de estudo: Observational_studies Limite: Child, preschool / Female / Humans / Infant / Male / Newborn Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Técnicas de Imagem de Sincronização Cardíaca / Técnicas de Imagem de Sincronização Respiratória / Cardiopatias Congênitas Tipo de estudo: Observational_studies Limite: Child, preschool / Female / Humans / Infant / Male / Newborn Idioma: En Ano de publicação: 2018 Tipo de documento: Article