Your browser doesn't support javascript.
loading
Dosimetric changes with computed tomography automatic tube-current modulation techniques.
Spampinato, Sofia; Gueli, Anna Maria; Milone, Pietro; Raffaele, Luigi Angelo.
Afiliação
  • Spampinato S; PH3DRA Laboratories (PHysics for Dating Diagnostic Dosimetry Research and Applications), Dipartimento di Fisica e Astronomia, Università di Catania and INFN-Catania, Via Santa Sofia 64, 95123, Catania, Italy. sofia.spampinato@ct.infn.it.
  • Gueli AM; Scuola di Specializzazione in Fisica Medica, Dipartimento di Scienze mediche chirurgiche e tecnologie avanzate "G. F. Ingrassia", Scuola Facoltà di Medicina, Via Santa Sofia 78, 95123, Catania, Italy. sofia.spampinato@ct.infn.it.
  • Milone P; Department of Oncology, Aarhus University Hospital, Nørrebrogade 44, 8000, Aarhus, Denmark. sofia.spampinato@ct.infn.it.
  • Raffaele LA; PH3DRA Laboratories (PHysics for Dating Diagnostic Dosimetry Research and Applications), Dipartimento di Fisica e Astronomia, Università di Catania and INFN-Catania, Via Santa Sofia 64, 95123, Catania, Italy.
Radiol Phys Technol ; 11(2): 184-191, 2018 Jun.
Article em En | MEDLINE | ID: mdl-29626289
The study is aimed at a verification of dose changes for a computed tomography automatic tube-current modulation (ATCM) technique. For this purpose, anthropomorphic phantom and Gafchromic® XR-QA2 films were used. Radiochromic films were cut according to the shape of two thorax regions. The ATCM algorithm is based on noise index (NI) and three exam protocols with different NI were chosen, of which one was a reference. Results were compared with dose values displayed by the console and with Poisson statistics. The information obtained with radiochromic films has been normalized with respect to the NI reference value to compare dose percentage variations. Results showed that, on average, the information reported by the CT console and calculated values coincide with measurements. The study allowed verification of the dose information reported by the CT console for an ATCM technique. Although this evaluation represents an estimate, the method can be a starting point for further studies.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article