Development of stability indicating HPLC method for the separation and validation of enantiomers of miconazole.
Bounoua, Nadia; Sekkoum, Khaled; Gumustas, Mehmet; Belboukhari, Nasser; Ozkan, Sibel A.
Afiliação
  • Bounoua N; Bioactive Molecules and Chiral Separation Laboratory, Faculty of Science and Technology, University of Béchar, Béchar, Algeria.
  • Sekkoum K; Bioactive Molecules and Chiral Separation Laboratory, Faculty of Science and Technology, University of Béchar, Béchar, Algeria.
  • Gumustas M; Department of Forensic Toxicology, Institute of Forensic Sciences, Ankara University, Ankara, Turkey.
  • Belboukhari N; Bioactive Molecules and Chiral Separation Laboratory, Faculty of Science and Technology, University of Béchar, Béchar, Algeria.
  • Ozkan SA; Department of Analytical Chemistry,Faculty of Pharmacy, Ankara University, Ankara, Turkey.
Chirality ; 30(6): 807-815, 2018 Jun.
Article em En | MEDLINE | ID: mdl-29637614
ABSTRACT
A selective and sensitive stability indicting HPLC method was developed for the analysis of enantiomers of miconazole. For this purpose, six different polysaccharide-based chiral columns were evaluated. Optimization was performed using several polar organic and alcohol-hydrocarbon mobile phases. As a result of optimization studies, the analysis was carried out using Lux Cellulose-3, methanol as a mobile phase at a flow rate of 1 mL·min-1 , and the detection wavelength was arranged to 230 nm. Developed method has been fully validated according to International Council on Harmonization guidelines. Method was found linear in the concentration range of 1 to 200 µg·mL-1 . Coefficient of determination (R2 ) was calculated as 0.9996, intraday precision of the method was found with the RSD% of 0.56, and the recovery of the method was calculated close to 100%. Furthermore, some other validation parameters like specificity, selectivity, LOD, and LOQ were also investigated. Stability indicating capability of this method was shown by forced degradation studies, and the run time for each analysis was less than 6 minutes. As a result, simple, fast, reliable HPLC method was developed for the separation and determination of the enantiomers of miconazole. Applicability of the developed method was shown with the application of marketed pharmaceutical preparations.