Your browser doesn't support javascript.
loading
Compact FTICR Mass Spectrometry for Real Time Monitoring of Volatile Organic Compounds.
Lemaire, Joël; Thomas, Sébastien; Lopes, Allan; Louarn, Essyllt; Mestdagh, Hélène; Latappy, Hubert; Leprovost, Julien; Heninger, Michel.
Afiliação
  • Lemaire J; Laboratoire de Chimie Physique, CNRS, Univ. Paris Sud, Université Paris Saclay, 91405 Orsay, France. joel.lemaire@u-psud.fr.
  • Thomas S; AlyXan, Centre Hoche, 91260 Juvisy-sur-Orge, France. sebastien.thomas@csnsm.in2p3.fr.
  • Lopes A; Laboratoire de Chimie Physique, CNRS, Univ. Paris Sud, Université Paris Saclay, 91405 Orsay, France. allan.lopes@u-psud.fr.
  • Louarn E; Laboratoire de Chimie Physique, CNRS, Univ. Paris Sud, Université Paris Saclay, 91405 Orsay, France. essyllt.louarn@u-psud.fr.
  • Mestdagh H; Laboratoire de Chimie Physique, CNRS, Univ. Paris Sud, Université Paris Saclay, 91405 Orsay, France. helene.mestdagh@u-psud.fr.
  • Latappy H; Laboratoire de Chimie Physique, CNRS, Univ. Paris Sud, Université Paris Saclay, 91405 Orsay, France. Hubert_Latappy@leco.com.
  • Leprovost J; AlyXan, Centre Hoche, 91260 Juvisy-sur-Orge, France. Hubert_Latappy@leco.com.
  • Heninger M; AlyXan, Centre Hoche, 91260 Juvisy-sur-Orge, France. julien.leprovost@alyxan.fr.
Sensors (Basel) ; 18(5)2018 May 03.
Article em En | MEDLINE | ID: mdl-29751541
ABSTRACT
In this paper, we present a compact Fourier transform ion cyclotron resonance mass spectrometer (FTICR-MS) designed for real time analysis of volatile organic compounds (VOCs) in air or in water. The spectrometer is based on a structured permanent magnet made with NdFeB segments. Chemical ionization is implemented inside the ICR cell. The most widely used reaction is the proton transfer reaction using H3O⁺ precursor ions, but other ionic precursors can be used to extend the range of species that can be detected. Complex mixtures are studied by switching automatically from one precursor to another. The accuracy obtained on the mass to charge ratio (Δm/z 5 × 10−3), allows a precise identification of the VOCs present and the limit of detection is 200 ppb without accumulation. The time resolution is a few seconds, mainly limited by the time necessary to come back to background pressure after the gas pulses. The real time measurement will be illustrated by the monitoring of VOCs produced during the thermal degradation of a polymer and by an example where three different precursor ions are used alternatively to monitor a gas sample.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article