Ultrasonography for noninvasive and real-time evaluation of peri-implant tissue dimensions.
Chan, Hsun-Liang; Sinjab, Khaled; Li, Junying; Chen, Zhaozhao; Wang, Hom-Lay; Kripfgans, Oliver D.
Afiliação
  • Chan HL; Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan.
  • Sinjab K; Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan.
  • Li J; Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan.
  • Chen Z; Department of Prosthodontics, West China School of Stomatology, Sichuan University, Chengdu, Sichuan, China.
  • Wang HL; Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan.
  • Kripfgans OD; Department of Prosthodontics, West China School of Stomatology, Sichuan University, Chengdu, Sichuan, China.
J Clin Periodontol ; 45(8): 986-995, 2018 08.
Article em En | MEDLINE | ID: mdl-29757464
AIM: Existing methods for evaluating marginal bone loss and tissue biotype around dental implants present with many limitations. The aim of this study was to examine the accuracy of high-resolution, 3-dimensional ultrasound to measure peri-implant tissue dimensions. MATERIAL AND METHODS: A 25-MHz ultrasound probe prototype was used to scan peri-implant tissues of 17 implants from seven fresh human cadavers. Four ultrasonic measurements were made as follows: the marginal bone level/thickness, and mucosal level/thickness. The readings were statistically compared to cone beam computed tomography (CBCT) and/or open bone measurements. RESULTS: The correlations (r) between the ultrasound and direct/CBCT readings of the four parameters ranged from 0.85 to 0.98 (p < 0.0001). The mean absolute difference in the four parameters between ultrasound-direct and ultrasound-CBCT ranged from 0.033 to 0.24 mm. CONCLUSION: Encouraging evidence is shown that ultrasound can accurately measure peri-implant tissue dimensions. Following clinical trial validations, ultrasound offers potential as a valuable tool to evaluate long-term peri-implant tissue stability without concerns of ionizing radiation and image artefacts around implants.