A Real-World Setting Study: Which Glucose Meter Could Be the Best for POCT Use? An Easy and Applicable Protocol During the Hospital Routine.
Mancini, Alessio; Esposto, Giampaolo; Manfrini, Silvana; Rilli, Silvia; Tinti, Gessica; Carta, Giuseppe; Petrolati, Laura; Vidali, Matteo; Barocci, Simone.
Afiliação
  • Mancini A; 1 School of Biosciences and Veterinary Medicine, University of Camerino, Camerino, Italy.
  • Esposto G; 2 ASUR MARCHE AV2, O.U. Clinical Pathology, Via Cellini, 1, Senigallia (AN), Italy.
  • Manfrini S; 3 Scuola di Specializzazione in Microbiologia e Virologia, Università degli Studi di Pisa, Lungarno Pacinotti, Pisa, Italy.
  • Rilli S; 4 Diabetology and Clinical Nutrition, Via Cellini, Senigallia, Italy.
  • Tinti G; 4 Diabetology and Clinical Nutrition, Via Cellini, Senigallia, Italy.
  • Carta G; 4 Diabetology and Clinical Nutrition, Via Cellini, Senigallia, Italy.
  • Petrolati L; 2 ASUR MARCHE AV2, O.U. Clinical Pathology, Via Cellini, 1, Senigallia (AN), Italy.
  • Vidali M; 2 ASUR MARCHE AV2, O.U. Clinical Pathology, Via Cellini, 1, Senigallia (AN), Italy.
  • Barocci S; 5 Servizio di Immunoematologia e Medicina Trasfusionale, Ospedale SS. Trinità, Borgomanero, Italy.
J Diabetes Sci Technol ; 12(5): 1053-1060, 2018 09.
Article em En | MEDLINE | ID: mdl-29783898
The aim of this retrospective study is to evaluate the reliability and robustness of six glucose meters for point-of-care testing in our wards using a brand-new protocol. During a 30-days study period a total of 50 diabetes patients were subjected to venous blood sampling and glucose meter blood analysis. The results of six glucose meters were compared with our laboratory reference assay. GlucoMen Plus (Menarini) with the 82% of acceptable results was the most robust glucose meter. Even if the Passing-Bablok analysis demonstrates the presence of constant systematic errors and the Bland-Altman test highlighted a possible overestimation, the surveillance error grid analysis showed that this glucose meter can be used safely. We proved that portable glucose meters are not always reliable in routinely clinical settings.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Glicemia / Automonitorização da Glicemia / Sistemas Automatizados de Assistência Junto ao Leito Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Glicemia / Automonitorização da Glicemia / Sistemas Automatizados de Assistência Junto ao Leito Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article