Your browser doesn't support javascript.
loading
CT perfusion imaging of lung cancer: benefit of motion correction for blood flow estimates.
Chu, Lisa L; Knebel, Robert J; Shay, Aryan D; Santos, Jonathan; Badawi, Ramsey D; Gandara, David R; Knollmann, Friedrich D.
Afiliação
  • Chu LL; Department of Radiology, University of California Davis Medical Center, 4860 Y Street, Suite 3100, Sacramento, CA, 95817, USA.
  • Knebel RJ; Department of Radiology, University of California Davis Medical Center, 4860 Y Street, Suite 3100, Sacramento, CA, 95817, USA.
  • Shay AD; Department of Radiology, University of California Davis Medical Center, 4860 Y Street, Suite 3100, Sacramento, CA, 95817, USA.
  • Santos J; Department of Radiology, University of California Davis Medical Center, 4860 Y Street, Suite 3100, Sacramento, CA, 95817, USA.
  • Badawi RD; Department of Radiology, University of California Davis Medical Center, 4860 Y Street, Suite 3100, Sacramento, CA, 95817, USA.
  • Gandara DR; Department of Internal Medicine, Division of Hematology and Oncology, University of California Davis Medical Center, Sacramento, CA, USA.
  • Knollmann FD; Department of Radiology, University of California Davis Medical Center, 4860 Y Street, Suite 3100, Sacramento, CA, 95817, USA. fknollmann@ucdavis.edu.
Eur Radiol ; 28(12): 5069-5075, 2018 Dec.
Article em En | MEDLINE | ID: mdl-29869174
PURPOSE: CT perfusion (CTP) imaging assessment of treatment response in advanced lung cancer can be compromised by respiratory motion. Our purpose was to determine whether an original motion correction method could improve the reproducibility of such measurements. MATERIALS AND METHODS: The institutional review board approved this prospective study. Twenty-one adult patients with non-resectable non-small-cell lung cancer provided written informed consent to undergo CTP imaging. A motion correction method that consisted of manually outlining the tumor margins and then applying a rigid manual landmark registration algorithm followed by the non-rigid diffeomorphic demons algorithm was applied. The non-motion-corrected and motion-corrected images were analyzed with dual blood supply perfusion analysis software. Two observers performed the analysis twice, and the intra- and inter-observer variability of each method was assessed with Bland-Altman statistics. RESULTS: The 95% limits of agreement of intra-observer reproducibility for observer 1 improved from -84.4%, 65.3% before motion correction to -33.8%, 30.3% after motion correction (r = 0.86 and 0.97, before and after motion correction, p < 0.0001 for both) and for observer 2 from -151%, 96% to -49 %, 36 % (r = 0.87 and 0.95, p < 0.0001 for both). The 95% limits of agreement of inter-observer reproducibility improved from -168%, 154% to -17%, 25%. CONCLUSION: The use of a motion correction method significantly improves the reproducibility of CTP estimates of tumor blood flow in lung cancer. KEY POINTS: • Tumor blood flow estimates in advanced lung cancer show significant variability. • Motion correction improves the reproducibility of CT blood flow estimates in advanced lung cancer. • Reproducibility of blood flow measurements is critical to characterize lung tumor biology and the success of treatment in lung cancer.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Carcinoma Pulmonar de Células não Pequenas / Neoplasias Pulmonares / Neovascularização Patológica Tipo de estudo: Guideline / Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Carcinoma Pulmonar de Células não Pequenas / Neoplasias Pulmonares / Neovascularização Patológica Tipo de estudo: Guideline / Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article