Your browser doesn't support javascript.
loading
Fractures After Removal of Spinal Instrumentation: Revisiting the Stress-Shielding Effect of Instrumentation in Spine Fusion.
Teles, Alisson R; Yavin, Daniel; Zafeiris, Christos P; Thomas, Kenneth C; Lewkonia, Peter; Nicholls, Fred H; Swamy, Ganesh; Jacobs, W Bradley.
Afiliação
  • Teles AR; McGill Scoliosis & Spine Group, McGill University, Montreal, Quebec, Canada. Electronic address: alisson.r.teles@gmail.com.
  • Yavin D; Division of Neurosurgery Spine Program, Department of Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada.
  • Zafeiris CP; Section of Orthopedic Surgery Spine Program, Department of Surgery, University of Calgary, Calgary, Alberta, Canada.
  • Thomas KC; Section of Orthopedic Surgery Spine Program, Department of Surgery, University of Calgary, Calgary, Alberta, Canada.
  • Lewkonia P; Section of Orthopedic Surgery Spine Program, Department of Surgery, University of Calgary, Calgary, Alberta, Canada.
  • Nicholls FH; Section of Orthopedic Surgery Spine Program, Department of Surgery, University of Calgary, Calgary, Alberta, Canada.
  • Swamy G; Section of Orthopedic Surgery Spine Program, Department of Surgery, University of Calgary, Calgary, Alberta, Canada.
  • Jacobs WB; Division of Neurosurgery Spine Program, Department of Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada.
World Neurosurg ; 116: e1137-e1143, 2018 Aug.
Article em En | MEDLINE | ID: mdl-29870838
BACKGROUND: Many practicing spine surgeons believe that instrumentation can be removed during revision surgery in successful posterolateral or anterior spinal fusions, confirmed by computed tomography and intraoperative exploration. The stress-shielding effect of spinal instrumentation was well described in the late 1980s and 1990s but has not received recent attention. Despite the paucity of recent literature, concepts underlying the biology and biomechanics of the spinal fusion mass remain particularly salient given the increasing incidence of revision spinal fusion surgery. The aim of this study was to highlight a potential complication of instrumentation removal owing to stress shielding of instrumentation on the spinal column and fusion mass. METHODS: A retrospective review was performed, and a small case series was described. RESULTS: In 3 cases, despite apparent solid fusion demonstrated on preoperative computed tomography and confirmed by intraoperative exploration, new fractures developed after removal of instrumentation. In these cases, fracture occurred at the transition zone between the newly rigid instrumented area and previous fusion. This highlights the relative weakness of the fusion and may be explained by the stress-shielding effect of instrumentation within the fusion mass. CONCLUSIONS: Spinal instrumentation revision requires careful consideration, and routine implant removal should not be performed. The presence of a solid fusion on computed tomography and/or at intraoperative exploration may not justify implant removal in these cases. In cases of extension of a fusion, use of a bridging connection to the new implants should be considered. The cases presented demonstrate the consequences of the stress-shielding effect of implants on the spine and fusion mass.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doenças da Coluna Vertebral / Fusão Vertebral / Fraturas Ósseas / Vértebras Lombares Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doenças da Coluna Vertebral / Fusão Vertebral / Fraturas Ósseas / Vértebras Lombares Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article