Your browser doesn't support javascript.
loading
Capillary electrophoresis-laser-induced fluorescence (CE-LIF)-based immunoassay for quantifying antibodies against cyclic citrullinated peptides.
Nguyen, Binh Thanh; Park, Min; Yoo, Young Sook; Kang, Min-Jung.
Afiliação
  • Nguyen BT; Molecular Recognition Research Center, Korea Institute of Science and Technology (KIST), Seoul 02792, Korea. mjkang1@kist.re.kr and Division of Bio-Medical Science and Technology (Biological Chemistry), University of Science and Technology (UST), Daejeon 34113, Korea.
  • Park M; Department of Materials Science and Engineering, Hallym University, Chuncheon-si, Korea and Integrative Materials Research Institute, Hallym University, Chuncheon-si, Korea.
  • Yoo YS; Molecular Recognition Research Center, Korea Institute of Science and Technology (KIST), Seoul 02792, Korea. mjkang1@kist.re.kr.
  • Kang MJ; Molecular Recognition Research Center, Korea Institute of Science and Technology (KIST), Seoul 02792, Korea. mjkang1@kist.re.kr and Division of Bio-Medical Science and Technology (Biological Chemistry), University of Science and Technology (UST), Daejeon 34113, Korea.
Analyst ; 143(13): 3141-3147, 2018 Jul 07.
Article em En | MEDLINE | ID: mdl-29877533
ABSTRACT
We developed an assay for diagnosing rheumatoid arthritis (RA) by capillary electrophoresis with the laser-induced fluorescence detection (CE-LIF) of antibodies against cyclic citrullinated peptides (CCPs) using fluorescein isothiocyanate-labeled F-CCP11A and F-CCP. The CCPs were incubated overnight with a purified antibody against CCP and then injected into the CE-LIF system to estimate complex concentration. The immunocomplexes and free peptides were separated within 5 min; the LOD and LOQ values of the immunoassay are 0.1 µg mL-1 and 0.3 µg mL-1, respectively. The calibration curves for the immunocomplex had a coefficient of determination of 0.98. The reproducibility of the CE-LIF based immunoassay when using F-CCP11A and F-CCP was less than 5% and the accuracy ranged between 89 and 103%. The applicability of the assay was evaluated using serum samples from RA patients and healthy control subjects. We found that the sensitivity and specificity for RA diagnosis were 100% and 83.3%, respectively, for F-CCP11A and 100% and 90%, respectively, for F-CCP. These results demonstrate that the CE-LIF method can be useful for quantitative immunoassay development.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artrite Reumatoide / Imunoensaio / Eletroforese Capilar / Anticorpos Antiproteína Citrulinada Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artrite Reumatoide / Imunoensaio / Eletroforese Capilar / Anticorpos Antiproteína Citrulinada Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article