Your browser doesn't support javascript.
loading
Novel use of a 3-dimensional mapping system in cryoablation of right-sided and septal accessory pathways: playback ablation.
Ishidoya, Yuki; Yotsukura, Akihiko; Sano, Fumihiko; Suzuki, George; Nanbu, Tadafumi; Yoshida, Izumi; Sakurai, Masayuki.
Afiliação
  • Ishidoya Y; Division of Cardiovascular Medicine, Hokko Memorial Hospital, North-27, East-8, Higashi-ku, Sapporo, 065-0027, Japan. ishidoya.yuuki@gmail.com.
  • Yotsukura A; Division of Cardiovascular Medicine, Hokko Memorial Hospital, North-27, East-8, Higashi-ku, Sapporo, 065-0027, Japan.
  • Sano F; Division of Cardiovascular Medicine, Hokko Memorial Hospital, North-27, East-8, Higashi-ku, Sapporo, 065-0027, Japan.
  • Suzuki G; Division of Cardiovascular Medicine, Hokko Memorial Hospital, North-27, East-8, Higashi-ku, Sapporo, 065-0027, Japan.
  • Nanbu T; Division of Cardiovascular Medicine, Hokko Memorial Hospital, North-27, East-8, Higashi-ku, Sapporo, 065-0027, Japan.
  • Yoshida I; Division of Cardiovascular Medicine, Hokko Memorial Hospital, North-27, East-8, Higashi-ku, Sapporo, 065-0027, Japan.
  • Sakurai M; Division of Cardiovascular Medicine, Hokko Memorial Hospital, North-27, East-8, Higashi-ku, Sapporo, 065-0027, Japan.
J Interv Card Electrophysiol ; 53(1): 91-101, 2018 Oct.
Article em En | MEDLINE | ID: mdl-29948588
ABSTRACT

PURPOSE:

Despite recent advances in the treatment of eliminating accessory pathways (APs), catheter-induced mechanical block (bump) of APs has been reported to result in a less favorable outcome with high primary failure and recurrence rates. The real bump site cannot always be precisely reapproached under fluoroscopy so physicians can perform ablation to a location different from where the mechanical block was encountered. In this paper, we describe this novel use of a 3-dimensional (3D) mapping system (playback ablation) with a case series.

METHODS:

The EnSite Velocity system (St. Jude Medical, St. Paul, MN, USA), a 3D mapping system, has a unique function that records the positional information of catheters in a 3D geometric map and the local potential of catheters continuously. This function enables physicians to specify the bump site in a 3D geometric map and apply ablation to the bump site even if the catheter moves away from the bump site.

RESULTS:

This technique helped us eliminate APs in two patients with bump of APs, and they have been free of preexcitation and arrhythmias without the use of anti-arrhythmic drugs for more than 3 months.

CONCLUSIONS:

This technique may contribute to improving long-term success in patients with mechanical block of APs.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Criocirurgia / Imageamento Tridimensional / Cirurgia Assistida por Computador / Eletrocardiografia / Feixe Acessório Atrioventricular Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Humans / Male Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Criocirurgia / Imageamento Tridimensional / Cirurgia Assistida por Computador / Eletrocardiografia / Feixe Acessório Atrioventricular Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Humans / Male Idioma: En Ano de publicação: 2018 Tipo de documento: Article