Your browser doesn't support javascript.
loading
Multiple-Point Evaluation Algorithms for Enhanced Precision of Pathogen-Specific Cerebrospinal Fluid/Serum Antibody Index Calculation.
Osterman, Andreas; Späth, Patricia M; Jäger, Gundula; Böhm, Stephan; Osterman, Peter.
Afiliação
  • Osterman A; 1 Max von Pettenkofer-Institute, Virology, National Reference Center for Retroviruses, Faculty of Medicine, LMU München, Munich, Germany.
  • Späth PM; 2 German Center for Infection Research (DZIF), partner site Munich, Munich, Germany.
  • Jäger G; 1 Max von Pettenkofer-Institute, Virology, National Reference Center for Retroviruses, Faculty of Medicine, LMU München, Munich, Germany.
  • Böhm S; 2 German Center for Infection Research (DZIF), partner site Munich, Munich, Germany.
  • Osterman P; 1 Max von Pettenkofer-Institute, Virology, National Reference Center for Retroviruses, Faculty of Medicine, LMU München, Munich, Germany.
SLAS Technol ; 24(1): 96-104, 2019 Feb.
Article em En | MEDLINE | ID: mdl-29949398
The determination of pathogen-specific antibody indices (AIs) of CSF and serum is an essential cornerstone in assessing neurological diseases and demands reliable high precision. Various companies provide ELISA kits for the detection of respective antibody concentrations and base AI calculation on a single CSF/serum pair of optical densities (ODs), combined with selection rules. The remainder of OD measurements is not used. There is no averaging of measurement errors and result stabilization. OD data from Siemens Enzygnost ELISA measurements of 2012-2016 proficiency survey samples for measles/rubella/varicella zoster/herpes simplex virus (MRZH) reaction (INSTAND e.V.) were reanalyzed. Several reference methods for calculating Q values from ODs using multiple-point evaluation are described. The methods are based on the α method and the four-parameter logistic (4PL) equation. Statistical analysis shows standard deviations of relative AI differences from AI target values to be significantly lower if derived from multiple-point evaluation instead of single-pair evaluation. Thus, the virus-averaged hit rate of a 10% target AI environment can be improved from 49% up to 69%. Waiving the usage of a standard curve in favor of parameter fitting significantly improves calculational precision for Siemens Enzygnost assays. Patient safety, diagnostic assay costs, and laboratory effectiveness might be improved for other test distributors as well.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Viroses / Ensaio de Imunoadsorção Enzimática / Líquido Cefalorraquidiano / Técnicas de Laboratório Clínico / Soro / Fatores Imunológicos / Anticorpos Antivirais Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Viroses / Ensaio de Imunoadsorção Enzimática / Líquido Cefalorraquidiano / Técnicas de Laboratório Clínico / Soro / Fatores Imunológicos / Anticorpos Antivirais Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article