Your browser doesn't support javascript.
loading
Novel mandibular advancement bite block with supplemental oxygen to both nasal and oral cavity improves oxygenation during esophagogastroduodenoscopy: a bench comparison.
Teng, Wei-Nung; Ting, Chien-Kun; Wang, Yu-Tzu; Yang, Kuang-Yao; Tsou, Mei-Yung; Orr, Joseph A; Burk, Kyle M; Chiang, Huihua; Lin, Chun-Li.
Afiliação
  • Teng WN; Department of Anaesthesiology, Taipei Veterans General Hospital and National Yang-Ming University, No. 201, Sec 2, Shipei Road, Beitou District, Taipei City, 11217, Taiwan, ROC.
  • Ting CK; Department of Biomedical Engineering, National Yang-Ming University, No. 155, Sec 2, Linong Street, Beitou District, Taipei City, 11221, Taiwan, ROC.
  • Wang YT; Department of Anaesthesiology, Taipei Veterans General Hospital and National Yang-Ming University, No. 201, Sec 2, Shipei Road, Beitou District, Taipei City, 11217, Taiwan, ROC.
  • Yang KY; Department of Biomedical Engineering, National Yang-Ming University, No. 155, Sec 2, Linong Street, Beitou District, Taipei City, 11221, Taiwan, ROC.
  • Tsou MY; Department of Chest Medicine, Taipei Veterans General Hospital, No. 201, Sec 2, Shipei Road, Beitou District, Taipei City, 11217, Taiwan, ROC.
  • Orr JA; Department of Anaesthesiology, Taipei Veterans General Hospital and National Yang-Ming University, No. 201, Sec 2, Shipei Road, Beitou District, Taipei City, 11217, Taiwan, ROC.
  • Burk KM; Department of Anesthesiology and Biomedical Engineering, University of Utah, Salt Lake City, UT, USA.
  • Chiang H; Department of Anesthesiology and Biomedical Engineering, University of Utah, Salt Lake City, UT, USA.
  • Lin CL; Department of Biomedical Engineering, National Yang-Ming University, No. 155, Sec 2, Linong Street, Beitou District, Taipei City, 11221, Taiwan, ROC. hkchiang@ym.edu.tw.
J Clin Monit Comput ; 33(3): 523-530, 2019 Jun.
Article em En | MEDLINE | ID: mdl-29974302
ABSTRACT
Drug-induced respiratory depression is a major cause of serious adverse events. Adequate oxygenation is very important during sedated esophagogastroduodenoscopy (EGD). Nasal breathing often shifts to oral breathing during open mouth EGD. A mandibular advancement bite block was developed for EGD using computer-assisted design and three-dimensional printing techniques. The mandible is advanced when using this bite block to facilitate airway opening. The device is composed of an oxygen inlet with one opening directed towards the nostril and another opening directed towards the oral cavity. The aim of this bench study was to compare the inspired oxygen concentration (FiO2) provided by the different nasal cannulas, masks, and bite blocks commonly used in sedated EGD. A manikin head was connected to one side of a two-compartment lung model by a 7.0 mm endotracheal tube with its opening in the nasopharyngeal position. The other compartment was driven by a ventilator to mimic "patient" inspiratory effort. Using this spontaneously breathing lung model, we evaluated five nasal cannulas, two face masks, and four new oral bite blocks at different oxygen flow rates and different mouth opening sizes. The respiratory rate was set at 12/min with a tidal volume of 500 mL and 8/min with a tidal volume of 300 mL. Several Pneuflo resistors of different sizes were used in the mouth of the manikin head to generate different degrees of mouth opening. FiO2 was evaluated continuously via the endotracheal tube. All parameters were evaluated using a Datex anesthesia monitoring system. The mandibular advancement bite block provided the highest FiO2 under the same supplemental oxygen flow. The FiO2 was higher for devices with oxygen flow provided via an oral bite block than that provided via the nasal route. Under the same supplemental oxygen flow, the tidal volume and respiratory rate also played an important role in the FiO2. A low respiratory rate with a smaller tidal volume has a relative high FiO2. The ratio of nasal to oral breathing played an important role in the FiO2 under hypoventilation but less role under normal ventilation. Bite blocks deliver a higher FiO2 during EGD. The ratio of nasal to oral breathing, supplemental oxygen flow, tidal volume, and respiratory rate influenced the FiO2 in most of the supplemental oxygen devices tested, which are often used for conscious sedation in patients undergoing EGD and colonoscopy.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oxigênio / Ventiladores Mecânicos / Endoscopia do Sistema Digestório / Avanço Mandibular Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oxigênio / Ventiladores Mecânicos / Endoscopia do Sistema Digestório / Avanço Mandibular Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article