Your browser doesn't support javascript.
loading
Extending Single Molecule Imaging to Proteome Analysis by Quantitation of Fluorescent Labeling Homogeneity in Complex Protein Samples.
Leclerc, Simon; Arntz, Youri; Taniguchi, Yuichi.
Afiliação
  • Leclerc S; Laboratory for Cell Systems Control , RIKEN Center for Biosystems Dynamics Research , 6-2-3 Furuedai , Suita , Osaka 565-0874 , Japan.
  • Arntz Y; Laboratoire de Biomatériaux et Bioimagerie , INSERM 1121 Université de Strasbourg, Faculté de Médecine , 4 rue Human , F-67000 Strasbourg , France.
  • Taniguchi Y; Laboratoire de Biomatériaux et Bioimagerie , INSERM 1121 Université de Strasbourg, Faculté de Médecine , 4 rue Human , F-67000 Strasbourg , France.
Bioconjug Chem ; 29(8): 2541-2549, 2018 08 15.
Article em En | MEDLINE | ID: mdl-29975043
ABSTRACT
Fluorescence-based electrophoresis has been widely used for proteome analysis in which every protein species in cells is labeled with a fluorescent dye, separated by electric migration, and quantified using fluorescence detection. The ultimate limit of sensitivity for this approach could be reached by single-molecule fluorescence imaging and counting individual proteins, requiring exhaustive fluorescent labeling of proteins across molecular populations and species. However, it remains unclear how homogeneous the fluorescence labeling of individual protein molecules of each species is across the proteome. To address this question, we developed a method to measure the labeling homogeneity based on a single-molecule fluorescence counting assay. Our results reveal that the proportion of proteins labeled with at least one dye, called labeling occupancy (LO), was 35% for fluorescently labeled BSA using existing protocols. We then found that the LO could be improved to 82% under high pH and surfactant-rich conditions. Furthermore, when a proteome sample from a human cell lysate was analyzed, the total LO was 71%, whereby the values varied between 50 and 90% for low and high molecular weight proteome fractions, respectively. The results support the possibility of sensitive detection of proteins using single-molecule counting with fluorescent labeling at the proteome scale.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Proteoma / Corantes Fluorescentes / Imagem Individual de Molécula Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article