Your browser doesn't support javascript.
loading
The rationale and design of the SMART CRT trial.
Gold, Michael R; Auricchio, Angelo; Leclercq, Christophe; Lowy, Jonathan; Rials, Seth J; Shoda, Morio; Tomassoni, Gery; Yong, Patrick; Wold, Nicholas; Ellenbogen, Kenneth A.
Afiliação
  • Gold MR; Department of Medicine, Medical University of South Carolina, SC, USA.
  • Auricchio A; Director Clinical Electrophysiology Program, Division of Cardiology, Fondazione Cardiocentro Ticino, Lugano, Switzerland.
  • Leclercq C; CHRU Hopital Pontchaillou, France.
  • Lowy J; Medical Director of Cardiac Research, PeaceHealth Southwest Medical Center, Vancouver, WA, USA.
  • Rials SJ; Grant Medical Center and the OhioHealth Research Institute, Columbus, OH, USA.
  • Shoda M; Tokyo Medical University Hospital, Tokyo, Japan.
  • Tomassoni G; Baptist Health Lexington, Lexington, KY, USA.
  • Yong P; Clinical Science, Boston Scientific Corp., St. Paul, MN, USA.
  • Wold N; Clinical Science, Boston Scientific Corp., St. Paul, MN, USA.
  • Ellenbogen KA; Martha and Harold Kimmerling Professor, Department of Medicine, Virginia Commonwealth University School of Medicine, Richmond, VA, USA.
Pacing Clin Electrophysiol ; 41(9): 1212-1216, 2018 09.
Article em En | MEDLINE | ID: mdl-30058174
ABSTRACT

AIMS:

The SMART CRT study will assess the efficacy of an atrioventricular optimization algorithm to improve reverse remodeling among patients undergoing cardiac resynchronization therapy (CRT) in the presence of interventricular electrical delay. METHODS AND

RESULTS:

The SMART CRT study is a global, multicenter, prospective, randomized study of patients undergoing CRT implantation. The primary endpoint of this trial is response rate to CRT, defined as decrease in left ventricular end-systolic volume (LVESV) ≥15% at 6 months compared to preimplant baseline. Additional prespecified analyses are (1) clinical composite endpoint combining all-cause mortality, heart failure events, New York Heart Association class, and Quality of Life (using a patient global assessment instrument); (2) the individual components of the clinical composite endpoint; (3) 6-minute walk distance; (4) Kansas City Cardiomyopathy Questionnaire; (5) LVESV as a continuous variable; and (6) absolute left-ventricular ejection fraction. Subjects with intraventricular delay ≥ 70 ms measured between the right ventricular and left ventricular pacing leads will be randomized in a 11 ratio to have either an AV Delay and pacing chamber determined by SmartDelay™ or a Fixed AV Delay of 120 ms with biventricular pacing. Enrollment of an estimated 726 of subjects from up to 100 centers worldwide is planned to achieve 436 randomized subjects and 370 complete data sets required to power the primary endpoint.

CONCLUSIONS:

This trial will provide important data regarding the importance of AV Delay programming in patients with prolonged interventricular delay at the pacing sites.
Assuntos
Palavras-chave

Texto completo: 1 Eixos temáticos: Pesquisa_clinica Base de dados: MEDLINE Assunto principal: Projetos de Pesquisa / Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca Tipo de estudo: Clinical_trials / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Eixos temáticos: Pesquisa_clinica Base de dados: MEDLINE Assunto principal: Projetos de Pesquisa / Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca Tipo de estudo: Clinical_trials / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article