Your browser doesn't support javascript.
loading
Tryptophan-like fluorescence as a measure of microbial contamination risk in groundwater.
Nowicki, Saskia; Lapworth, Dan J; Ward, Jade S T; Thomson, Patrick; Charles, Katrina.
Afiliação
  • Nowicki S; University of Oxford, School of Geography and the Environment, Oxford OX1 3QY, UK. Electronic address: saskia.nowicki@ouce.ox.ac.uk.
  • Lapworth DJ; British Geological Survey, Maclean Building, Wallingford OX10 8BB, UK.
  • Ward JST; British Geological Survey, Maclean Building, Wallingford OX10 8BB, UK; University of Surrey, Department of Civil and Environmental Engineering, Guildford GU2 7XH, UK.
  • Thomson P; University of Oxford, School of Geography and the Environment, Oxford OX1 3QY, UK.
  • Charles K; University of Oxford, School of Geography and the Environment, Oxford OX1 3QY, UK.
Sci Total Environ ; 646: 782-791, 2019 Jan 01.
Article em En | MEDLINE | ID: mdl-30064104
ABSTRACT
Microbial water quality is frequently assessed with a risk indicator approach that relies on Escherichia coli. Relying exclusively on E. coli is limiting, particularly in low-resource settings, and we argue that risk assessments could be improved by a complementary parameter, tryptophan-like fluorescence (TLF). Over two campaigns (June 2016 and March 2017) we sampled 37 water points in rural Kwale County, Kenya for TLF, E. coli and thermotolerant coliforms (total n = 1082). Using three World Health Organization defined classes (very high, high, and low/intermediate), risk indicated by TLF was not significantly different from risk indicated by E. coli (p = 0.85). However, the TLF and E. coli risk classifications did show disagreement, with TLF indicating higher risk for 14% of samples and lower risk for 13% of samples. Comparisons of duplicate/replicate results demonstrated that precision is higher for TLF (average relative percent difference of duplicates = 14%) compared to culture-based methods (average RPD of duplicates ≥ 26%). Additionally, TLF sampling is more practical because it requires less time and resources. Precision and practicality make TLF well-suited to high-frequency sampling in low resource contexts. Interpretation and interference challenges are minimised when TLF is measured in groundwaters, which typically have low dissolved organic carbon, relatively consistent temperature, negligible turbidity and pH between 5 and 8. TLF cannot be used as a proxy for E. coli on an individual sample basis, but it can add value to groundwater risk assessments by improving prioritization of sampling and by increasing understanding of spatiotemporal variability.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Microbiologia da Água / Água Subterrânea / Monitoramento Ambiental Tipo de estudo: Etiology_studies / Risk_factors_studies País como assunto: Africa Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Microbiologia da Água / Água Subterrânea / Monitoramento Ambiental Tipo de estudo: Etiology_studies / Risk_factors_studies País como assunto: Africa Idioma: En Ano de publicação: 2019 Tipo de documento: Article