Your browser doesn't support javascript.
loading
Target-triggered signal-on ratiometric electrochemiluminescence sensing of PSA based on MOF/Au/G-quadruplex.
Shao, Kang; Wang, Biru; Nie, Axiu; Ye, Shiyi; Ma, Jing; Li, Zhonghua; Lv, Zhicheng; Han, Heyou.
Afiliação
  • Shao K; State Key Laboratory of Agricultural Microbiology, College of Science, Huazhong Agricultural University, Wuhan 430070, PR China.
  • Wang B; State Key Laboratory of Agricultural Microbiology, College of Science, Huazhong Agricultural University, Wuhan 430070, PR China.
  • Nie A; State Key Laboratory of Agricultural Microbiology, College of Science, Huazhong Agricultural University, Wuhan 430070, PR China.
  • Ye S; State Key Laboratory of Agricultural Microbiology, College of Science, Huazhong Agricultural University, Wuhan 430070, PR China.
  • Ma J; State Key Laboratory of Agricultural Microbiology, College of Science, Huazhong Agricultural University, Wuhan 430070, PR China.
  • Li Z; State Key Laboratory of Agricultural Microbiology, College of Science, Huazhong Agricultural University, Wuhan 430070, PR China.
  • Lv Z; State Key Laboratory of Agricultural Microbiology, College of Science, Huazhong Agricultural University, Wuhan 430070, PR China.
  • Han H; State Key Laboratory of Agricultural Microbiology, College of Science, Huazhong Agricultural University, Wuhan 430070, PR China. Electronic address: hyhan@mail.hzau.edu.cn.
Biosens Bioelectron ; 118: 160-166, 2018 Oct 30.
Article em En | MEDLINE | ID: mdl-30075386
Signal-amplified ratiometric electrochemiluminescence (Sa-RECL) provides an attractive approach to maximize signal-to-noise ratio through enhancing signals and eliminate interferences. In this work, we prepared a novel metal-organic framework (MOF)/Au/G-quadruplex as both quenchers and enhancers to fabricate a target-triggered ratiometric ECL sensor for high sensitive and accurate detection of prostatic specific antigen (PSA). The ratiometric ECL sensor using the dual-potential-dependent ECL emitters (quantum dots (QDs) and luminol) and MOF/Au/G-quadruplex not only achieved signal self-calibration but also realized cooperative amplification. After the sequential hybridization among of complementary DNA-QDs, PSA aptamer and pDNA-Au-Hemin-MIL-DNAzyme and the further competition of PSA, the pDNA-Au-Hemin-MIL-DNAzyme probe would keep away from the electrode surface, causing a switchover of their ECL signals from "off-on" state to "on-off" state. The ratiometric ECL aptasensor exhibits high-sensitive and accurate analytical performance toward PSA with a linear detection range from 0.5 to 500 ng mL-1 and a detection limit of 0.058 ng mL-1 (S/N = 3). The novel ratiometric ECL biosensor has been successfully applied to determine different serum samples of PSA, indicating its potential application in the clinical diagnosis.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise Química do Sangue / Técnicas Biossensoriais / Antígeno Prostático Específico / Técnicas Eletroquímicas / Medições Luminescentes Limite: Humans / Male Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise Química do Sangue / Técnicas Biossensoriais / Antígeno Prostático Específico / Técnicas Eletroquímicas / Medições Luminescentes Limite: Humans / Male Idioma: En Ano de publicação: 2018 Tipo de documento: Article