Chitosan-magnetite nanocomposite as a sensing platform to bendiocarb determination.
de Oliveira, Raissa C; Sousa, Camila P; Freire, Tiago M; Freire, Rafael M; Denardin, Juliano C; Fechine, Pierre B A; Becker, Helena; Morais, Simone; de Lima-Neto, Pedro; Correia, Adriana N.
Afiliação
  • de Oliveira RC; Departamento de Química Analítica e Físico-Química, Centro de Ciências, Universidade Federal do Ceará, Bloco 940, Campus do Pici, Pici, Fortaleza, CE, 60440-900, Brazil.
  • Sousa CP; Departamento de Química Analítica e Físico-Química, Centro de Ciências, Universidade Federal do Ceará, Bloco 940, Campus do Pici, Pici, Fortaleza, CE, 60440-900, Brazil. pinheiro.cs@gmail.com.
  • Freire TM; Departamento de Química Analítica e Físico-Química, Centro de Ciências, Universidade Federal do Ceará, Bloco 940, Campus do Pici, Pici, Fortaleza, CE, 60440-900, Brazil.
  • Freire RM; Departamento de Física, Universidade de Santiago de Chile, Av. Ecuador, 3493, Santiago, Chile.
  • Denardin JC; Center for the Development of Nanoscience and Nanotechnology (CEDENNA), 917-0124, Santiago, Chile.
  • Fechine PBA; Departamento de Física, Universidade de Santiago de Chile, Av. Ecuador, 3493, Santiago, Chile.
  • Becker H; Center for the Development of Nanoscience and Nanotechnology (CEDENNA), 917-0124, Santiago, Chile.
  • Morais S; Departamento de Química Analítica e Físico-Química, Centro de Ciências, Universidade Federal do Ceará, Bloco 940, Campus do Pici, Pici, Fortaleza, CE, 60440-900, Brazil.
  • de Lima-Neto P; Departamento de Química Analítica e Físico-Química, Centro de Ciências, Universidade Federal do Ceará, Bloco 940, Campus do Pici, Pici, Fortaleza, CE, 60440-900, Brazil.
  • Correia AN; REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4200-072, Porto, Portugal.
Anal Bioanal Chem ; 410(27): 7229-7238, 2018 Nov.
Article em En | MEDLINE | ID: mdl-30151686
A novel platform for carbamate-based pesticide quantification using a chitosan/magnetic iron oxide (Chit-Fe3O4) nanocomposite as a glassy carbon electrode (GCE) modifier is shown for an analytical methodology for determination of bendiocarb (BND). The BND oxidation signal using GCE/Chit-Fe3O4 compared with bare GCE was catalyzed, showing a 37.5% of current increase with the peak potential towards less positive values, showing method's increased sensitivity and selectivity. Using square-wave voltammetry (SWV), calibration curves for BND determination were obtained (n = 3), and calculated detection and quantification limits values were 2.09 × 10-6 mol L-1 (466.99 ppb) and 6.97 × 10-6 mol L-1 (1555.91 ppb), respectively. The proposed electroanalytical methodology was successfully applied for BND quantification in natural raw waters without any sample pretreatment, proving that the GCE/Chit-Fe3O4 modified electrode showed great potential for BND determination in complex samples. ᅟ Graphical abstract.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article