Blood Coagulation Testing Smartphone Platform Using Quartz Crystal Microbalance Dissipation Method.
Yao, Jia; Feng, Bin; Zhang, Zhiqi; Li, Chuanyu; Zhang, Wei; Guo, Zhen; Zhao, Heming; Zhou, Lianqun.
Afiliação
  • Yao J; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China. yaojia@sibet.ac.cn.
  • Feng B; School of Electronic and Information Engineering, Soochow University, Suzhou 215006, China. yaojia@sibet.ac.cn.
  • Zhang Z; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China. fengbincn@foxmail.com.
  • Li C; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China. zhangzhiqi@sibet.ac.cn.
  • Zhang W; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China. lichy@sibet.ac.cn.
  • Guo Z; University of Chinese Academy of Sciences, Beijing 100049, China. lichy@sibet.ac.cn.
  • Zhao H; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China. zhangw@sibet.ac.cn.
  • Zhou L; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China. guozhen@sibet.ac.cn.
Sensors (Basel) ; 18(9)2018 Sep 13.
Article em En | MEDLINE | ID: mdl-30217015
ABSTRACT
Blood coagulation function monitoring is important for people who are receiving anticoagulation treatment and a portable device is needed by these patients for blood coagulation self-testing. In this paper, a novel smartphone based blood coagulation test platform was proposed. It was developed based on parylene-C coated quartz crystal microbalance (QCM) dissipation measuring and analysis. The parylene-C coating constructed a robust and adhesive surface for fibrin capturing. The dissipation factor was obtained by measuring the frequency response of the sensor. All measured data were sent to a smartphone via Bluetooth for dissipation calculation and blood coagulation results computation. Two major coagulation indexes, activated partial thromboplastin time (APTT) and prothrombin time (PT) were measured on this platform compared with results by a commercial hemostasis system in a clinical laboratory. The measurement results showed that the adjusted R-square (R²) value for APTT and PT measurements were 0.985 and 0.961 respectively. The QCM dissipation method for blood coagulation measurement was reliable and effective and the platform together with the QCM dissipation method was a promising solution for point of care blood coagulation testing.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Testes de Coagulação Sanguínea / Técnicas de Microbalança de Cristal de Quartzo / Smartphone Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Testes de Coagulação Sanguínea / Técnicas de Microbalança de Cristal de Quartzo / Smartphone Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article