Your browser doesn't support javascript.
loading
Cryo scanning transmission x-ray microscope optimized for spectrotomography.
Leontowich, A F G; Berg, R; Regier, C N; Taylor, D M; Wang, J; Beauregard, D; Geilhufe, J; Swirsky, J; Wu, J; Karunakaran, C; Hitchcock, A P; Urquhart, S G.
Afiliação
  • Leontowich AFG; Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada.
  • Berg R; Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada.
  • Regier CN; Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada.
  • Taylor DM; Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada.
  • Wang J; Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada.
  • Beauregard D; Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada.
  • Geilhufe J; Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada.
  • Swirsky J; Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada.
  • Wu J; Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario L8S 4M1, Canada.
  • Karunakaran C; Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada.
  • Hitchcock AP; Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario L8S 4M1, Canada.
  • Urquhart SG; Department of Chemistry, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5C9, Canada.
Rev Sci Instrum ; 89(9): 093704, 2018 Sep.
Article em En | MEDLINE | ID: mdl-30278741
A cryo scanning transmission X-ray microscope, the cryo-STXM, has been designed and commissioned at the Canadian Light Source synchrotron. The instrument is designed to operate from 100 to 4000 eV (λ = 12.4 - 0.31 nm). Users can insert a previously frozen sample, through a load lock, and rotate it ±70° in the beam to collect tomographic data sets. The sample can be maintained for extended periods at 92 K primarily to suppress radiation damage and a pressure on the order of 10-9 Torr to suppress sample contamination. The achieved spatial resolution (30 nm) and spectral resolution (0.1 eV) are similar to other current soft X-ray STXMs, as demonstrated by measurements on known samples and test patterns. The data acquisition efficiency is significantly more favorable for both imaging and tomography. 2D images, 3D tomograms, and 4D chemical maps of automotive hydrogen fuel cell thin sections are presented to demonstrate current performance and new capabilities, namely, cryo-spectrotomography in the soft X-ray region.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article