Your browser doesn't support javascript.
loading
Ultrasound Evaluation of Anterior Acromioclavicular Relationship in the Horizontal Plane on 40 Healthy Subjects. A New Possibility for Differential Diagnosis of Acromioclavicular Disjunctions Rockwood Stage 3 and 4? A Pilot Study.
Villatte, Guillaume; Lecointe, Thibault; Erivan, Roger; Mulliez, Aurélien; Métais, Pierre; Descamps, Stéphane; Boisgard, Stéphane.
Afiliação
  • Villatte G; Service d'Orthopédie-Traumatologie, Hôpital Gabriel Montpied, CHU de Clermont Ferrand, Clermont Ferrand, France.
  • Lecointe T; SIGMA Clermont, Institut de Chimie de Clermont-Ferrand, Université Clermont Auvergne, Clermont-Ferrand, France.
  • Erivan R; CNRS, UMR 6296, ICCF, Aubière, France.
  • Mulliez A; Service d'Orthopédie-Traumatologie, Hôpital Gabriel Montpied, CHU de Clermont Ferrand, Clermont Ferrand, France.
  • Métais P; Service d'Orthopédie-Traumatologie, Hôpital Gabriel Montpied, CHU de Clermont Ferrand, Clermont Ferrand, France.
  • Descamps S; SIGMA Clermont, Institut de Chimie de Clermont-Ferrand, Université Clermont Auvergne, Clermont-Ferrand, France.
  • Boisgard S; CNRS, UMR 6296, ICCF, Aubière, France.
Clin J Sport Med ; 30(6): e219-e224, 2020 11.
Article em En | MEDLINE | ID: mdl-30312184
ABSTRACT

OBJECTIVE:

To evaluate the repeatability and reproducibility of an ultrasound examination of the acromioclavicular joint (ACJ) performed by an orthopaedic surgeon to analyze anterior ACJ relationship in the horizontal plane.

DESIGN:

Prospective observational study on healthy subjects.

SETTING:

The study was conducted in 2017 in a university department of orthopaedic surgery and traumatology. LEVEL OF EVIDENCE III. PATIENTS (OR PARTICIPANTS) Forty consecutive volunteers aged 18 to 40 years were involved. INTERVENTIONS (OR ASSESSMENT OF RISK FACTORS OR INDEPENDENT VARIABLES) The ultrasound examination was performed by 2 orthopaedic surgeons with a SonoSite M-Turbo portable ultrasound machine (Fujifilm, Japan). Distance measurement between the anterior edge of the clavicle (AECL) and the anterior edge of the acromion (AEAC) was done on the right side, then on the left one and repeated by the same examiner. MAIN OUTCOME

MEASURES:

The intra- and interexaminer reproducibility of measurements was analyzed as primary outcome. Concordance of distance measurements between the right and left sides on the same subject was evaluated, as well as the "typical morphology" of the ACJ in the horizontal plane.

RESULTS:

The intra- and interexaminer reproducibility for AECL-AEAC distance measurements was, respectively, 0.95 (0.93-0.97) and 0.87 (0.84-0.90). The correlation between the right and left sides was significant (P < 0.001), with a reproducibility of 0.86 (0.83-0.89). Twenty-seven (67.5%) volunteers were considered to have a "perfect alignment" of the AECL and AEAC.

CONCLUSIONS:

This study confirms that it is possible to evaluate with good reproducibility the anterior AC relationship in the horizontal plane and that both sides are similar on the same subject.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Articulação Acromioclavicular / Ultrassonografia Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Articulação Acromioclavicular / Ultrassonografia Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2020 Tipo de documento: Article