Your browser doesn't support javascript.
loading
Design and raytrace simulations of a multilayer-coated Wolter x-ray optic for the Z machine at Sandia National Laboratories.
Vogel, J K; Pivovaroff, M J; Kozioziemski, B; Walton, C C; Ayers, J; Bell, P; Bradley, D; Descalle, M-A; Hau-Riege, S; Pickworth, L A; Ampleford, D J; Ball, C R; Bourdon, C J; Fein, J R; Gard, P D; Maurer, A; Wu, M; Ames, A; Bruni, R; Romaine, S; Kilaru, K; Roberts, O J; Ramsey, B.
Afiliação
  • Vogel JK; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Pivovaroff MJ; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Kozioziemski B; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Walton CC; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Ayers J; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Bell P; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Bradley D; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Descalle MA; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Hau-Riege S; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Pickworth LA; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Ampleford DJ; Sandia National Laboratories, Albuquerque, New Mexico 87123, USA.
  • Ball CR; Sandia National Laboratories, Albuquerque, New Mexico 87123, USA.
  • Bourdon CJ; Sandia National Laboratories, Albuquerque, New Mexico 87123, USA.
  • Fein JR; Sandia National Laboratories, Albuquerque, New Mexico 87123, USA.
  • Gard PD; Sandia National Laboratories, Albuquerque, New Mexico 87123, USA.
  • Maurer A; Sandia National Laboratories, Albuquerque, New Mexico 87123, USA.
  • Wu M; Sandia National Laboratories, Albuquerque, New Mexico 87123, USA.
  • Ames A; Smithsonian Astrophysical Observatory, Cambridge, Massachusetts 02138, USA.
  • Bruni R; Smithsonian Astrophysical Observatory, Cambridge, Massachusetts 02138, USA.
  • Romaine S; Smithsonian Astrophysical Observatory, Cambridge, Massachusetts 02138, USA.
  • Kilaru K; Universities Space Research Association, Huntsville, Alabama 35805, USA.
  • Roberts OJ; Universities Space Research Association, Huntsville, Alabama 35805, USA.
  • Ramsey B; NASA Marshall Space Flight Center, Huntsville, Alabama 35812, USA.
Rev Sci Instrum ; 89(10): 10G113, 2018 Oct.
Article em En | MEDLINE | ID: mdl-30399826
ABSTRACT
Recent breakthroughs in the fabrication of small-radii Wolter optics for astrophysics allow high energy density facilities to consider such optics as novel x-ray diagnostics at photon energies of 15-50 keV. Recently, the Lawrence Livermore National Laboratory, Sandia National Laboratories (SNL), the Smithsonian Astrophysical Observatory, and the NASA Marshall Space Flight Center jointly developed and fabricated the first custom Wolter microscope for implementation in SNL's Z machine with optimized sensitivity at 17.5 keV. To achieve spatial resolution of order 100-200 microns over a field of view of 5 × 5 × 5 mm3 with high throughput and narrow energy bandpass, the geometry of the optic and its multilayer required careful design and optimization. While the geometry mainly influences resolution and the field of view of the diagnostic, the mirror coating determines the spectral response and throughput. Here we outline the details of the design and fabrication process for the first multilayer-coated Wolter I optic for SNL's Z machine (Z Wolter), including its W/Si multilayer, and present results of raytrace simulations completed to predict and verify the performance of the optic.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article