Probable reinfection with Legionella pneumophila - A case report.
Buchholz, Udo; Reber, Franziska; Lehfeld, Ann-Sophie; Brodhun, Bonita; Haas, Walter; Schaefer, Benedikt; Stemmler, Fabian; Otto, Christina; Gagell, Corinna; Lück, Christian; Gamradt, Ronny; Heinig, Maxi; Meisel, Christian; Kölsch, Uwe; Eisenblätter, Martin; Jahn, Heiko J.
Afiliação
  • Buchholz U; Robert Koch Institute, Seestr. 10, Berlin, Germany. Electronic address: buchholzu@rki.de.
  • Reber F; Robert Koch Institute, Seestr. 10, Berlin, Germany. Electronic address: reberf@rki.de.
  • Lehfeld AS; Robert Koch Institute, Seestr. 10, Berlin, Germany. Electronic address: lehfelda@rki.de.
  • Brodhun B; Robert Koch Institute, Seestr. 10, Berlin, Germany. Electronic address: brodhunb@rki.de.
  • Haas W; Robert Koch Institute, Seestr. 10, Berlin, Germany. Electronic address: haasw@rki.de.
  • Schaefer B; German Environment Agency, Bad Elster, Germany. Electronic address: benedikt.schaefer@uba.de.
  • Stemmler F; German Environment Agency, Bad Elster, Germany. Electronic address: fabian.stemmler@uba.de.
  • Otto C; German Environment Agency, Bad Elster, Germany. Electronic address: christina.otto@uba.de.
  • Gagell C; Institute for Medical Microbiology and Hygiene, Medical Faculty "Carl Gustav Carus", Technical University Dresden, Germany. Electronic address: corinna.gagell@mailbox.tu-dresden.de.
  • Lück C; Institute for Medical Microbiology and Hygiene, Medical Faculty "Carl Gustav Carus", Technical University Dresden, Germany. Electronic address: christian.lueck@mailbox.tu-dresden.de.
  • Gamradt R; Health Department of Neukölln, Berlin, Germany. Electronic address: ronny.gamradt@bezirksamt-neukoelln.de.
  • Heinig M; Health Department of Neukölln, Berlin, Germany. Electronic address: maxi.heinig@bezirksamt-neukoelln.de.
  • Meisel C; Labor Berlin, Berlin, Germany. Electronic address: christian.meisel@laborberlin.com.
  • Kölsch U; Labor Berlin, Berlin, Germany. Electronic address: uwe.koelsch@laborberlin.com.
  • Eisenblätter M; SynLab, Berlin, Germany. Electronic address: martin.eisenblaetter@synlab.com.
  • Jahn HJ; Robert Koch Institute, Seestr. 10, Berlin, Germany. Electronic address: JahnH@rki.de.
Int J Hyg Environ Health ; 222(2): 315-318, 2019 03.
Article em En | MEDLINE | ID: mdl-30501994
ABSTRACT
In Germany community-acquired Legionnaires' disease is usually caused by the species Legionella pneumophila. Recurrent cases of Legionnaires' disease are rarely reported and are due either to a second infection (reinfection) or a relapse of a previous case. We report a case of recurrent Legionnaires' disease in an 86-year-old female patient infected with Legionella pneumophila serogroup 1, monoclonal antibody-subtype Knoxville, sequence type unknown. Between the two disease incidents the patient had completely recovered. Legionella pneumophila was detected with the monoclonal antibody-subtype Knoxville, sequence type 182, in the drinking water of the patient's apartment. Exposure to contaminated drinking water was interrupted after the first incident exposure through the application of point-of-use water filters. The filters were later removed due to low water pressure, and the second illness occurred thereafter. It is unclear if immunological predisposition has contributed to this case of probable reinfection of Legionnaires' disease. Clinical, microbiological and epidemiological information combined suggest this is a case of reinfection of Legionnaires' disease. In cases of recurrent Legionnaires' disease complete collection of patient and water samples is necessary to differentiate relapse from reinfection cases, to implicate the source of infection and to gain more evidence for the role of immunological predisposition.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença dos Legionários / Legionella pneumophila Limite: Aged80 / Female / Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença dos Legionários / Legionella pneumophila Limite: Aged80 / Female / Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article