Your browser doesn't support javascript.
loading
Acetabular reinforcement ring with additional hook improves stability in three-dimensional finite element analyses of dysplastic hip arthroplasty.
Totoribe, Koji; Chosa, Etsuo; Yamako, Go; Zhao, Xin; Ouchi, Koki; Hamada, Hiroaki; Deng, Gang.
Afiliação
  • Totoribe K; Department of Orthopaedic Surgery, Faculty of Medicine, University of Miyazaki, 5200 Kihara, Kiyotake, Miyazaki, 889-1692, Japan.
  • Chosa E; Department of Orthopaedic Surgery, Faculty of Medicine, University of Miyazaki, 5200 Kihara, Kiyotake, Miyazaki, 889-1692, Japan.
  • Yamako G; Department of Mechanical Design Systems, Faculty of Engineering, University of Miyazaki, 1-1 Gakuen Kibana-dai-Nishi, Miyazaki, 889-2192, Japan. g.yamako@cc.miyazaki-u.ac.jp.
  • Zhao X; Department of Orthopaedic Surgery, Faculty of Medicine, University of Miyazaki, 5200 Kihara, Kiyotake, Miyazaki, 889-1692, Japan.
  • Ouchi K; Department of Mechanical Design Systems, Faculty of Engineering, University of Miyazaki, 1-1 Gakuen Kibana-dai-Nishi, Miyazaki, 889-2192, Japan.
  • Hamada H; Department of Orthopaedic Surgery, Faculty of Medicine, University of Miyazaki, 5200 Kihara, Kiyotake, Miyazaki, 889-1692, Japan.
  • Deng G; Department of Mechanical Design Systems, Faculty of Engineering, University of Miyazaki, 1-1 Gakuen Kibana-dai-Nishi, Miyazaki, 889-2192, Japan.
J Orthop Surg Res ; 13(1): 313, 2018 Dec 07.
Article em En | MEDLINE | ID: mdl-30526630
BACKGROUND: The stability of acetabulum reconstructions using reinforcement rings and hooks is important for successful replacement surgery. The objective of this study was to biomechanically determine the effects of the hook on stress and the related micromotions of the acetabular reinforcement ring during the immediate postoperative period. METHODS: Acetabular reinforcement ring models were developed using a nonlinear, three-dimensional, finite element method. Using a pre-prepared template, we constructed without-hook and bone graft models of varying volumes and material properties. RESULTS: The stress on the inferior margin of the acetabulum was higher in the with-hook model than in the without-hook model, especially with increased bone graft volumes, and the stiffness of the bone graft material was decreased. Relative micromotions in the without-hook model were higher than in the with-hook models. The highest relative micromotion was observed in the model with increased bone graft volume and lower stiffness of bone graft material. CONCLUSIONS: In biomechanical analyses, the hook effectively dispersed stress and improved the initial fixation strength of the acetabular reinforcement ring.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Instrumentos Cirúrgicos / Artroplastia de Quadril / Análise de Elementos Finitos / Imageamento Tridimensional / Acetábulo Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Instrumentos Cirúrgicos / Artroplastia de Quadril / Análise de Elementos Finitos / Imageamento Tridimensional / Acetábulo Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article