Your browser doesn't support javascript.
loading
Plasma Concentrations of Myeloid-Derived Growth Factor in Healthy Individuals and Patients with Acute Myocardial Infarction as Assessed by Multiple Reaction Monitoring-Mass Spectrometry.
Polten, Felix; Reboll, Marc R; Widera, Christian; Kempf, Tibor; Bethmann, Kerstin; Gupta, Priyanka; Miglietta, John; Pekcec, Anton; Tillmanns, Jochen; Bauersachs, Johann; Giannitsis, Evangelos; Pich, Andreas; Wollert, Kai C.
Afiliação
  • Widera C; Department of Cardiology , University of Oldenburg , Rahel-Straus-Str. 10 , 26133 Oldenburg , Germany.
  • Gupta P; Boehringer Ingelheim Pharmaceuticals, Inc. , 900 Ridgebury Road , Ridgefield , Connecticut 06877 , United States.
  • Miglietta J; Boehringer Ingelheim Pharmaceuticals, Inc. , 900 Ridgebury Road , Ridgefield , Connecticut 06877 , United States.
  • Pekcec A; Boehringer Ingelheim Pharma GmbH & Co. KG , Birkendorfer Str. 65 , 88397 Biberach an der Riss , Germany.
  • Giannitsis E; Department of Medicine III , University of Heidelberg , Im Neuenheimer Feld 410 , 69120 Heidelberg , Germany.
Anal Chem ; 91(2): 1302-1308, 2019 01 15.
Article em En | MEDLINE | ID: mdl-30543396
ABSTRACT
Myeloid-derived growth factor (MYDGF in humans, Mydgf in mice) is a secreted protein with previously unknown biological functions. In a recent study, Mydgf was shown to mediate cardiac repair after acute myocardial infarction (MI) in mice. Lack of a sensitive assay to measure MYDGF in the circulation has hampered its further investigation. Here, we developed a liquid chromatography/multiple reaction monitoring-mass spectrometry MYDGF assay, employing SDS-PAGE-based protein fractionation to deplete high-abundant proteins and a stable isotope-labeled synthetic standard peptide for quantification. The assay had a lower limit of quantification of 0.8 ng/mL and a linear range up to 190 ng/mL. Within-run and total imprecision ranged from 8 to 17% and 11 to 20%, respectively. MYDGF plasma concentrations were not affected by either storage at room temperature for 4 h or up to three freeze-thaw cycles. Apparently healthy adults presented with a median (range) MYDGF concentration of 3.3 (1.3-6.7) ng/mL ( n = 120). MYDGF concentrations were elevated 2.7-fold ( P < 0.001) in patients with acute MI ( n = 101) and were associated with inflammatory biomarkers, renal dysfunction, and long-term cardiovascular mortality. The new assay and the favorable preanalytic characteristics of the analyte will facilitate studies into the pathophysiology of MYDGF and its potential use as a biomarker or protein therapeutic in patients with acute MI or other disease states.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Cromatografia Líquida / Interleucinas / Infarto do Miocárdio Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Cromatografia Líquida / Interleucinas / Infarto do Miocárdio Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article