Your browser doesn't support javascript.
loading
Phytochemical standardization of Vasicinein cough syrup by high performance liquid chromatography-densitometry.
Rehman, Hina; Naveed, Safila; Qamar, Fatima; Ayaz, Sultan; Jamil, Sadia; Fatima, Sakina; Sana, Aisha; Usmanghani, Khan.
Afiliação
  • Rehman H; Department ofPharmacy Practice, Jinnah University for Women, Karachi, Pakistan / Faculty of Pharmacy, Jinnah University for Women, Karachi, Pakistan.
  • Naveed S; Faculty of Pharmacy, Jinnah University for Women, Karachi, Pakistan.
  • Qamar F; Faculty of Pharmacy, Jinnah University for Women, Karachi, Pakistan.
  • Ayaz S; Department of Eastern Medicine, GC University, Faisalabad, Pakistan.
  • Jamil S; Department of Pharmacy Practice, Dow University ofHealth Sciences, Karachi,Pakistan.
  • Fatima S; Faculty of Pharmacy, Jinnah University for Women, Karachi, Pakistan.
  • Sana A; Faculty of Pharmacy, Jinnah University for Women, Karachi, Pakistan.
  • Usmanghani K; Department ofPharmacy Practice, Jinnah University for Women, Karachi, Pakistan / Research and Development Department, Herbion Pakistan (Pvt.) Limited, Karachi, Pakistan.
Pak J Pharm Sci ; 31(6 (Supplementary): 2679-2682, 2018 Nov.
Article em En | MEDLINE | ID: mdl-30587479
ABSTRACT
The highly oriented modern detection techniques provide a precise and definite tool for investigation in natural medicines. Current study directed the standardization of eminent biomarker Vasicine in a natural cough syrup. A highly accurate and precise method of High-performance thin layer chromatography (HPTLC) has been developed to certify the quantity of vasicine inside the syrup. Ethyl acetate, chloroform, ethanol and ammonia (631 1 v/v) were mobile phase for the study. The TLC plate silica gel G60F254 was used with CAMAG Scanner III and CAMAG Linomate 5. The detected Rf value was 0.51 in both sample and reference standard at 254 nm. International conference of Harmonization (ICH) guidelines were followed for the validation of the developed method. Linearity was achieved in the range of 200µg to 1600µg with co-efficient correlation r2=0.9995. Accuracy was found in between 98.9 to 101.4% however precision was good at both inter and intra-day. As per the standardization of ICH, the developed method was found to be reproducible and showed sharp similar peak with high resolution.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Antitussígenos / Quinazolinas / Densitometria / Alcaloides / Compostos Fitoquímicos Idioma: En Ano de publicação: 2018 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Antitussígenos / Quinazolinas / Densitometria / Alcaloides / Compostos Fitoquímicos Idioma: En Ano de publicação: 2018 Tipo de documento: Article