Your browser doesn't support javascript.
loading
A Wearable Transient Pressure Sensor Made with MXene Nanosheets for Sensitive Broad-Range Human-Machine Interfacing.
Guo, Ying; Zhong, Mengjuan; Fang, Zhiwei; Wan, Pengbo; Yu, Guihua.
Afiliação
  • Guo Y; State Key Laboratory of Organic-Inorganic Composites , Beijing University of Chemical Technology , Beijing 100029 , China.
  • Zhong M; State Key Laboratory of Chemical Resource Engineering , Beijing University of Chemical Technology , Beijing 100029 , PR China.
  • Fang Z; State Key Laboratory of Organic-Inorganic Composites , Beijing University of Chemical Technology , Beijing 100029 , China.
  • Wan P; Materials Science and Engineering Program and Department of Mechanical Engineering , The University of Texas , Austin , Texas 78712 , United States.
  • Yu G; State Key Laboratory of Organic-Inorganic Composites , Beijing University of Chemical Technology , Beijing 100029 , China.
Nano Lett ; 19(2): 1143-1150, 2019 02 13.
Article em En | MEDLINE | ID: mdl-30657695
ABSTRACT
Flexible and degradable pressure sensors have received tremendous attention for potential use in transient electronic skins, flexible displays, and intelligent robotics due to their portability, real-time sensing performance, flexibility, and decreased electronic waste and environmental impact. However, it remains a critical challenge to simultaneously achieve a high sensitivity, broad sensing range (up to 30 kPa), fast response, long-term durability, and robust environmental degradability to achieve full-scale biomonitoring and decreased electronic waste. MXenes, which are two-dimensional layered structures with a large specific surface area and high conductivity, are widely employed in electrochemical energy devices. Here, we present a highly sensitive, flexible, and degradable pressure sensor fabricated by sandwiching porous MXene-impregnated tissue paper between a biodegradable polylactic acid (PLA) thin sheet and an interdigitated electrode-coated PLA thin sheet. The flexible pressure sensor exhibits high sensitivity with a low detection limit (10.2 Pa), broad range (up to 30 kPa), fast response (11 ms), low power consumption (10-8 W), great reproducibility over 10 000 cycles, and excellent degradability. It can also be used to predict the potential health status of patients and act as an electronic skin (E-skin) for mapping tactile stimuli, suggesting potential in personal healthcare monitoring, clinical diagnosis, and next-generation artificial skins.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2019 Tipo de documento: Article