The Crystal Backlighter Imager: A spherically bent crystal imager for radiography on the National Ignition Facility.
Hall, G N; Krauland, C M; Schollmeier, M S; Kemp, G E; Buscho, J G; Hibbard, R; Thompson, N; Casco, E R; Ayers, M J; Ayers, S L; Meezan, N B; Hopkins, L F Berzak; Nora, R; Hammel, B A; Masse, L; Field, J E; Bradley, D K; Bell, P; Landen, O L; Kilkenny, J D; Mariscal, D; Park, J; McCarville, T J; Lowe-Webb, R; Kalantar, D; Kohut, T; Piston, K.
Afiliação
  • Hall GN; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Krauland CM; General Atomics, P.O. Box 85608, San Diego, California 92186-5608, USA.
  • Schollmeier MS; Sandia National Laboratories, Albuquerque, New Mexico 87185, USA.
  • Kemp GE; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Buscho JG; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Hibbard R; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Thompson N; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Casco ER; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Ayers MJ; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Ayers SL; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Meezan NB; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Hopkins LFB; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Nora R; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Hammel BA; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Masse L; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Field JE; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Bradley DK; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Bell P; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Landen OL; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Kilkenny JD; General Atomics, P.O. Box 85608, San Diego, California 92186-5608, USA.
  • Mariscal D; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Park J; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • McCarville TJ; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Lowe-Webb R; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Kalantar D; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Kohut T; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
  • Piston K; Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550, USA.
Rev Sci Instrum ; 90(1): 013702, 2019 Jan.
Article em En | MEDLINE | ID: mdl-30709218
The Crystal Backlighter Imager (CBI) is a quasi-monochromatic, near-normal incidence, spherically bent crystal imager developed for the National Ignition Facility (NIF), which will allow inertial confinement fusion capsule implosions to be radiographed close to stagnation. This is not possible using the standard pinhole-based area-backlighter configuration, as the self-emission from the capsule hotspot overwhelms the backlighter signal in the final stages of the implosion. The CBI mitigates the broadband self-emission from the capsule hot spot by using the extremely narrow bandwidth inherent to near-normal-incidence Bragg diffraction. Implementing a backlighter system based on near-normal reflection in the NIF chamber presents unique challenges, requiring the CBI to adopt novel engineering and operational strategies. The CBI currently operates with an 11.6 keV backlighter, making it the highest energy radiography diagnostic based on spherically bent crystals to date. For a given velocity, Doppler shift is proportional to the emitted photon energy. At 11.6 keV, the ablation velocity of the backlighter plasma results in a Doppler shift that is significant compared to the bandwidth of the instrument and the width of the atomic line, requiring that the shift be measured to high accuracy and the optics aligned accordingly to compensate. Experiments will be presented that used the CBI itself to measure the backlighter Doppler shift to an accuracy of better than 1 eV. These experiments also measured the spatial resolution of CBI radiographs at 7.0 µm, close to theoretical predictions. Finally, results will be presented from an experiment in which the CBI radiographed a capsule implosion driven by a 1 MJ NIF laser pulse, demonstrating a significant (>100) improvement in the backlighter to self-emission ratio compared to the pinhole-based area-backlighter configuration.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article