An accelerometer-based navigation did not improve the femoral component positioning compared to a modified conventional technique of pre-operatively planned placement of intramedullary rod in total knee arthroplasty.
Tsukeoka, Tadashi; Tsuneizumi, Yoshikazu; Yoshino, Kensuke.
Afiliação
  • Tsukeoka T; Department of Orthopaedic Surgery, Chiba Rehabilitation Center, 1-45-2 Hondacho, Midori-ku, Chiba, 266-0005, Japan. mdddd940@ybb.ne.jp.
  • Tsuneizumi Y; Department of Orthopaedic Surgery, Chiba Rehabilitation Center, 1-45-2 Hondacho, Midori-ku, Chiba, 266-0005, Japan.
  • Yoshino K; Department of Orthopaedic Surgery, Chiba University, Chiba, Japan.
Arch Orthop Trauma Surg ; 139(4): 561-567, 2019 Apr.
Article em En | MEDLINE | ID: mdl-30756166

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fixadores Internos / Artroplastia do Joelho / Cirurgia Assistida por Computador / Fêmur / Acelerometria Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article