Your browser doesn't support javascript.
loading
Synthetic hydroxyapatite and its use in bioactive coatings.
Guillen-Romero, Luis Daniel; Oropeza-Guzmán, Mercedes Teresita; López-Maldonado, Eduardo Alberto; Iglesias, Ana Leticia; Paz-González, Juan Antonio; Ng, Theodore; Serena-Gómez, Eduardo; Villarreal-Gómez, Luis Jesús.
Afiliação
  • Guillen-Romero LD; 1 Escuela de Ciencias de la Ingeniería y Tecnología, Universidad Autónoma de Baja California, Unidad Valle de las Palmas, Tijuana, Baja California, México.
  • Oropeza-Guzmán MT; 2 Centro de Graduados, Instituto Tecnológico de Tijuana, Tijuana, Baja California, México.
  • López-Maldonado EA; 3 Facultad de Ciencias Químicas e Ingeniería, Universidad Autónoma de Baja California, Unidad Otay, Tijuana, Baja California, México.
  • Iglesias AL; 1 Escuela de Ciencias de la Ingeniería y Tecnología, Universidad Autónoma de Baja California, Unidad Valle de las Palmas, Tijuana, Baja California, México.
  • Paz-González JA; 1 Escuela de Ciencias de la Ingeniería y Tecnología, Universidad Autónoma de Baja California, Unidad Valle de las Palmas, Tijuana, Baja California, México.
  • Ng T; 4 Oakland Oral and Maxillofacial Surgery, Oakland, California, United States.
  • Serena-Gómez E; 5 Escuela de Ciencias de la Salud, Universidad Autónoma de Baja California, Unidad Valle de las Palmas, Tijuana, Baja California, México.
  • Villarreal-Gómez LJ; 1 Escuela de Ciencias de la Ingeniería y Tecnología, Universidad Autónoma de Baja California, Unidad Valle de las Palmas, Tijuana, Baja California, México.
J Appl Biomater Funct Mater ; 17(1): 2280800018817463, 2019.
Article em En | MEDLINE | ID: mdl-30803286
ABSTRACT
An approach to solve the limitations of autologous bone grafting procedures in bone injury treatment is to develop bioactive coatings in the implantation system. The objective of this work is to compare the temperature effect on the stability of hydroxyapatite, graphene, and collagen colloidal suspensions to be used as biocompatible and bioactive coatings on a carbon fiber composite surface. Synthesized hydroxyapatite was assessed by X-ray diffraction. Zeta potential at different temperatures was evaluated. Specimens were characterized using scanning electron microscopy and Raman analysis. The results showed that the best hydroxyapatite/graphene ratio was 85/15, while those of the hydroxyapatite/collagen mixtures were 85/15. A hydroxyapatite/graphene/collagen mixture was synthesized based on these results.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Durapatita Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Durapatita Idioma: En Ano de publicação: 2019 Tipo de documento: Article