Your browser doesn't support javascript.
loading
Acute safety, effectiveness, and real-world clinical usage of ultra-high density mapping for ablation of cardiac arrhythmias: results of the TRUE HD study.
Hindricks, Gerhard; Weiner, Stanislav; McElderry, Tom; Jaïs, Pierre; Maddox, William; Garcia-Bolao, Jose Ignacio; Yong Ji, Sang; Sacher, Frederic; Willems, Stephan; Mounsey, John; Maury, Philippe; Bollmann, Andreas; Duffy, Elizabeth; Raciti, Giovanni; Tung, Roderick; Wong, Tom.
Afiliação
  • Hindricks G; Department of Electrophysiology, Heart Center Leipzig, Strümpellstr., Leipzig, Germany.
  • Weiner S; Clinic Electrophysiology Department, Trinity Mother Frances, Tyler, TX, USA.
  • McElderry T; Cardiac Electrophysiology, Division of Cardiovascular Disease, University of Alabama Birmingham, Birmingham, AL, USA.
  • Jaïs P; Electrophysiology and Ablation Unit, University of Bordeaux, CHU Bordeaux, IHU LIRYC, Bordeaux, France.
  • Maddox W; Cardiac Electrophysiology, Division of Cardiovascular Disease, University of Alabama Birmingham, Birmingham, AL, USA.
  • Garcia-Bolao JI; Arrhythmia Unit, Cardiology Service, University of Navarra, Pamplona, Spain.
  • Yong Ji S; Cardiac Electrophysiology, Division of Cardiology, Torrance Memorial Medical Center, Torrance, CA, USA.
  • Sacher F; Electrophysiology and Ablation Unit, University of Bordeaux, CHU Bordeaux, IHU LIRYC, Bordeaux, France.
  • Willems S; Department of Cardiac Electrophysiology, University Medical Center Hamburg Eppendorf, Hamburg, Germany.
  • Mounsey J; Division of Cardiology, University of North Carolina Hospitals, Chapel Hill, NC, USA.
  • Maury P; Division of Cardiology, University Hospital Rangueil, Toulouse, France.
  • Bollmann A; Department of Electrophysiology, Heart Center Leipzig, Strümpellstr., Leipzig, Germany.
  • Duffy E; Rhythm Management, Boston Scientific, St. Paul, MN, USA.
  • Raciti G; Rhythm Management, Boston Scientific, St. Paul, MN, USA.
  • Tung R; Center for Arrhythmia Care, Heart and Vascular Center, The University of Chicago Medicine, Chicago, IL, USA.
  • Wong T; Heart Rhythm Centre, Royal Brompton and Harefield foundation Trust and Imperial College, London, UK.
Europace ; 21(4): 655-661, 2019 Apr 01.
Article em En | MEDLINE | ID: mdl-30815690
ABSTRACT

AIMS:

The objective of this study was to verify acute safety, performance, and usage of a novel ultra-high density mapping system in patients undergoing ablation procedure in a real-world clinical setting. METHODS AND

RESULTS:

The TRUE HD study enrolled patients undergoing catheter ablation with mapping for all arrhythmias (excluding de novo atrial fibrillation) who were followed for 1 month. Safety was determined by collecting all serious adverse events and adverse events associated with the study devices. Performance was determined as the composite of ability to map the arrhythmia/substrate, complete the ablation applications, arrhythmia termination (where applicable), and ablation validation. Use of mapping system in the ablation validation workflow was also evaluated. Among the 519 patients who underwent a complete (504) or attempted (15) procedure, 21 (4%) serious ablation-related complications were collected, with 3 (0.57%) potentially related to the mapping catheter. Four hundred and twenty treated patients resulted in a successful procedure confirmed by arrhythmia-specific validation techniques (83.3%; 95% confidence interval 79.8-86.5%). A total of 1419 electroanatomical maps were created with a median acquisition time of 923 min per map. Of these, 372 maps in 222 (44%) patients were collected for ablation validation purposes. Following validation mapping, 162/222 (73%) patients required additional ablation.

CONCLUSION:

In the TRUE HD study mapping was associated with rates of acute success and complications consistent with previously published reports. Importantly, a low percentage of events (0.57%) was attributed to the mapping catheter. When performed, validation mapping was useful for identifying additional targets for ablation in the majority of patients.
Assuntos
Palavras-chave

Texto completo: 1 Eixos temáticos: Pesquisa_clinica Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Ablação por Cateter / Técnicas Eletrofisiológicas Cardíacas Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Eixos temáticos: Pesquisa_clinica Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Ablação por Cateter / Técnicas Eletrofisiológicas Cardíacas Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article