Your browser doesn't support javascript.
loading
Percutaneous Portal Vein Embolization Using a Simplified Sheathless 18-Gauge Trocar Needle Approach: Review of Efficacy and Safety.
Wong, Simon Sin-Man; Yuen, Brian Tsz-Yau; Lee, Ryan Ka-Lok; Tsai, Chris Siu-Chun; Cheung, Yue Sun; Lee, Kit Fai; Yu, Simon Chun Ho.
Afiliação
  • Wong SS; Department of Imaging and Interventional Radiology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong.
  • Yuen BT; Department of Imaging and Interventional Radiology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong.
  • Lee RK; Department of Imaging and Interventional Radiology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong.
  • Tsai CS; Department of Imaging and Interventional Radiology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong.
  • Cheung YS; Department of Surgery, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong.
  • Lee KF; Department of Surgery, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong.
  • Yu SCH; Department of Imaging and Interventional Radiology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong. Electronic address: simonyu@cuhk.edu.hk.
J Vasc Interv Radiol ; 30(3): 440-444, 2019 03.
Article em En | MEDLINE | ID: mdl-30819490
ABSTRACT

PURPOSE:

Portal vein (PV) embolization (PVE) is traditionally performed via a PV sheath with selective embolization of PV branches. Here, the efficacy and safety of PVE with the use of only an 18-gauge needle is reported. MATERIALS AND

METHODS:

Consecutive patients who underwent PVE from 2009 through 2017 were retrospectively reviewed. Forty-five patients (mean age, 60 y ± 7.6; 38 men) underwent 45 PVE procedures. Hepatocellular carcinoma, cholangiocarcinoma, and metastases accounted for 26 (58%), 13 (29%), and 6 (13%) patients, respectively. PVE was performed by puncturing a branch of right PV with an 18-gauge needle under US guidance. Via the same needle, direct portography was performed, followed by PVE with an N-butyl cyanoacrylate/Lipiodol mixture. Percentage increase of future liver remnant (FLR) volume and increase in ratio of FLR to total liver volume were estimated as measures of efficacy. Complications were reported according to Society of Interventional Radiology classification. Fluoroscopy time, procedure time, and dose-area product (DAP) were recorded.

RESULTS:

Technical success rate was 100%. The median DAP, fluoroscopy time, and procedure time were 74,387 mGy·cm2 (IQR, 90,349 mGy·cm2), 3.5 min (IQR, 2.10 min), and 24 min (IQR, 10.5 min). Among the 23 patients with complete CT volumetry data, mean increase in the ratio of FLR to total liver volume and percentage increase of FLR volume were 12.5% ± 7.7 and 50% ± 33, respectively. There were 3 minor complications (asymptomatic nonocclusive emboli in FLR) and 3 major complications (1 hepatic vein emboli, 1 subphrenic collection, and 1 hepatic infarct).

CONCLUSIONS:

PVE via a sheathless 18-gauge needle approach is feasible, with satisfactory FLR hypertrophy.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Veia Porta / Neoplasias dos Ductos Biliares / Colangiocarcinoma / Óleo Etiodado / Carcinoma Hepatocelular / Embolização Terapêutica / Embucrilato / Neoplasias Hepáticas Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Veia Porta / Neoplasias dos Ductos Biliares / Colangiocarcinoma / Óleo Etiodado / Carcinoma Hepatocelular / Embolização Terapêutica / Embucrilato / Neoplasias Hepáticas Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Idioma: En Ano de publicação: 2019 Tipo de documento: Article