Your browser doesn't support javascript.
loading
Outcome and complications of adjustable continence therapy (ProACTTM ) in the treatment of urinary incontinence after transurethral resection of the prostate: A multicenter study.
Noordhoff, Toscane C; Finazzi-Agrò, Enrico; Scheepe, Jeroen R; Blok, Bertil F M.
Afiliação
  • Noordhoff TC; Department of Urology, Erasmus University Medical Center, Rotterdam, The Netherlands.
  • Finazzi-Agrò E; Department of Eperimental Medicine and Surgery, University of Rome "Tor Vergata", Urology Unit, Policlinico Tor Vergata, Rome, Italy.
  • Scheepe JR; Department of Urology, Erasmus University Medical Center, Rotterdam, The Netherlands.
  • Blok BFM; Department of Urology, Erasmus University Medical Center, Rotterdam, The Netherlands.
Neurourol Urodyn ; 38(4): 1111-1119, 2019 04.
Article em En | MEDLINE | ID: mdl-30848845
ABSTRACT

AIM:

To evaluate the outcome of adjustable continence balloons in the treatment of stress urinary incontinence (SUI) after transurethral resection of the prostate (TURP).

METHODS:

In two tertiary centers, adjustable continence balloons were implanted in 29 patients with post-TURP SUI between 2007 and 2018. Endpoints of this retrospective multicenter study were patient-reported changes in pad count and complications. Dry was defined as no pad or one security pad.

RESULTS:

Preoperative urinary incontinence was mild in 7 (24%), moderate in 12 (41%), and severe in 10 (35%) patients. The median follow-up duration was 21 (interquartile range [IQR], 11-43) months. Within 30 days postoperatively, a Clavien-Dindo grade less than or equal to II complication occurred in 24% of the patients. Reintervention rate was 24%. Six and 12 months after implantation, the International Prostate Symptom Score (IPSS) quality-of-life item improved significantly from 5 (IQR, 5-6) preoperatively to 3 (IQR, 1-4.5) and 1 (IQR, 0-3), respectively. At last visit (median 21 months after implantation), the outcome on continence had improved in 76% of the patients, including, 45% dry patients. After a median follow-up of 28 months (IQR, 13-63; N = 23), all but one patient reported improvement on the Patient Global Impression of Improvement (PGI-I) scale. In detail, 10 patients reported "very much better" condition compared with before the implantation, 10 patients "much better," two patients "a little better," and one patient "no change." Daily pad use decreased from three (IQR, 2-5) to one (IQR, 0-2) pads/day (P < 0.001).

CONCLUSIONS:

This is hitherto, the first study reporting results of adjustable continence balloons in the treatment of post-TURP SUI. The therapy was found to be safe and efficient. The majority of our study population reported improvement on their condition and greater than or equal to 50% reduction in daily pad use.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Qualidade de Vida / Incontinência Urinária / Ressecção Transuretral da Próstata / Oclusão com Balão Tipo de estudo: Observational_studies Limite: Aged / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Qualidade de Vida / Incontinência Urinária / Ressecção Transuretral da Próstata / Oclusão com Balão Tipo de estudo: Observational_studies Limite: Aged / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article